Add like
Add dislike
Add to saved papers

Identifying immunodeficiency status in children with pulmonary tuberculosis: using radiomics approach based on un-enhanced chest computed tomography.

Translational Pediatrics 2023 December 27
BACKGROUND: Children with primary immunodeficiency diseases (PIDs) are particularly vulnerable to infection of Mycobacterium tuberculosis (Mtb). Chest computed tomography (CT) is an important examination diagnosing pulmonary tuberculosis (PTB), and there are some differences between primary immunocompromised and immunocompetent cases with PTB. Therefore, this study aimed to use the radiomics analysis based on un-enhanced CT for identifying immunodeficiency status in children with PTB.

METHODS: This retrospective study enrolled a total of 173 patients with diagnosis of PTB and available immunodeficiency status. Based on their immunodeficiency status, the patients were divided into PIDs (n=72) and no-PIDs (n=101). The samplings were randomly divided into training and testing groups according to a ratio of 3:1. Regions of interest were obtained by segmenting lung lesions on un-enhanced CT images to extract radiomics features. The optimal radiomics features were identified after dimensionality reduction in the training group, and a logistic regression algorithm was used to establish radiomics model. The model was validated in the training and testing groups. Diagnostic efficiency of the model was evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, specificity, precision, accuracy, F1 score, calibration curve, and decision curve.

RESULTS: The radiomics model was constructed using nine optimal features. In the training set, the model achieved an AUC of 0.837, sensitivity of 0.783, specificity of 0.780, and F1 score of 0.749. The cross-validation of the model in the training set showed an AUC of 0.774, sensitivity of 0.834, specificity of 0.720, and F1 score of 0.749. In the test set, the model achieved an AUC of 0.746, sensitivity of 0.722, specificity of 0.692, and F1 score of 0.823. Calibration curves indicated a strong predictive performance by the model, and decision curve analysis demonstrated its clinical utility.

CONCLUSIONS: The CT-based radiomics model demonstrates good discriminative efficacy in identifying the presence of PIDs in children with PTB, and shows promise in accurately identifying the immunodeficiency status in this population.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app