Vanguard Study: Initial experience with the new fourth generation Pipeline Vantage Flow Diverter (PVFD): 6-month results, technical and clinical considerations.
Journal of Neurointerventional Surgery 2024 January 4
BACKGROUND: The Pipeline Embolization Device has proven to be a safe and effective device for the treatment of intracranial aneurysms. The Pipeline Vantage Flow Diverter (PVFD) with Shield Technology is the new fourth generation of this implant, with modifications made compared to previous iterations. We aimed to evaluate the mechanical properties and clinical safety and efficacy of this device.
METHODS: Vanguard is a single arm, single center, prospective study. Between April 2021 and April 2023, all consecutive patients with an unruptured aneurysm treated with Pipeline Vantage flow-diverting stents were included. There were no aneurysm size or location exclusion criteria. Safety (neurological serious adverse events) and efficacy (device deployment and aneurysm occlusion) were independently reviewed. Imaging follow-up data, and immediate, early (<30 days), and delayed (>30 days) neurological serious adverse events were independently assessed.
RESULTS: 101 consecutive patients with a total of 115 aneurysms were included. The aneurysms were situated in the anterior (90.4%) or posterior (9.6%) circulations. A total of 124 devices were implanted. The deployment success rate was 100%. In four (4.0%) cases post-deployment angioplasty was required to optimize device wall apposition. Occlusion rates at 1 month were 54.7%, at 3 months 72.1%, and at 6 months 81.7%. Morbidity and mortality were 4.9% and 0%, respectively, at 6 months. Eight cases (6.9%) demonstrated in-stent stenosis, four of which had 'fish mouth' deformity.
CONCLUSION: Initial results of the new generation PVFD for unruptured intracranial aneurysm treatment demonstrate overall satisfactory device performance, safety profile, and effectiveness.
METHODS: Vanguard is a single arm, single center, prospective study. Between April 2021 and April 2023, all consecutive patients with an unruptured aneurysm treated with Pipeline Vantage flow-diverting stents were included. There were no aneurysm size or location exclusion criteria. Safety (neurological serious adverse events) and efficacy (device deployment and aneurysm occlusion) were independently reviewed. Imaging follow-up data, and immediate, early (<30 days), and delayed (>30 days) neurological serious adverse events were independently assessed.
RESULTS: 101 consecutive patients with a total of 115 aneurysms were included. The aneurysms were situated in the anterior (90.4%) or posterior (9.6%) circulations. A total of 124 devices were implanted. The deployment success rate was 100%. In four (4.0%) cases post-deployment angioplasty was required to optimize device wall apposition. Occlusion rates at 1 month were 54.7%, at 3 months 72.1%, and at 6 months 81.7%. Morbidity and mortality were 4.9% and 0%, respectively, at 6 months. Eight cases (6.9%) demonstrated in-stent stenosis, four of which had 'fish mouth' deformity.
CONCLUSION: Initial results of the new generation PVFD for unruptured intracranial aneurysm treatment demonstrate overall satisfactory device performance, safety profile, and effectiveness.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app