Add like
Add dislike
Add to saved papers

Comparative Analysis of Diagnostic Performance of Automatic Breast Ultrasound, Full-Field Digital Mammography and Contrast-Enhanced Mammography in Relation to Breast Composition.

Biomedicines 2023 December 7
This single center study includes a comparative analysis of the diagnostic performance of full-field digital mammography (FFDM), contrast-enhanced mammography (CEM) and automatic breast ultrasound (ABUS) in the group of patients with breast American College of Radiology (ACR) categories C and D as well as A and B with FFDM. The study involved 297 patients who underwent ABUS and FFDM. Breast types C and D were determined in 40% of patients with FFDM and low- energy CEM. CEM was performed on 76 patients. Focal lesions were found in 131 patients, of which 115 were histopathologically verified. The number of lesions detected in patients with multiple lesions were 40 from 48 with ABUS, 13 with FFDM and 21 with CEM. Compliance in determining the number of foci was 82% for FFDM and 91% for both CEM and ABUS. In breast types C and D, 72% of all lesions were found with ABUS, 56% with CEM and 29% with FFDM ( p = 0.008, p = 0.000); all invasive cancers were diagnosed with ABUS, 83% with CEM and 59% with FFDM ( p = 0.000, p = 0.023); 100% DCIS were diagnosed with ABUS, 93% with CEM and 59% with FFDM. The size of lesions from histopathology in breast ACR categories A and B was 14-26 mm, while in breast categories C and D was 11-37 mm. In breast categories C and D, sensitivity of ABUS, FFDM and CEM was, respectively, 78.05, 85.37, 92.68; specificity: 40, 13.33, 8.33; PPV (positive predictive value): 78.05, 72.92, 77.55; NPV (negative predictive value): 40, 25, 25, accuracy: 67.86, 66.07, 73.58. In breast categories A and B, sensitivity of ABUS, FFDM and CEM was, respectively, 81.25, 93.75, 93.48; specificity: 18.18, 18.18, 16.67; PPV: 81.25, 83.33, 89.58; NPV: 18.18, 40, 25; accuracy: 69.49, 79.66, 84.62. The sensitivity of the combination of FFDM and ABUS was 100 for all types of breast categories; the accuracy was 75 in breast types C and D and 81.36 in breast types A and B. The study confirms the predominance of C and D breast anatomy types and the low diagnostic performance of FFDM within that group and indicates ABUS and CEM as potential additive methods in breast cancer diagnostics.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app