Comparison of two different TSH-receptor antibody assays: A clinical practice study.

Heliyon 2023 December
BACKGROUND: Graves' disease (GD) is caused by the production of TSH-receptor (TSHR) stimulating auto-antibodies. Over the years various TSHR-antibody (TRAb) detection assays have been developed. Most clinical laboratories use competitive TSH-binding inhibitory immunoglobulin (TBII) assays, which measure the total amount of stimulating and blocking auto-antibodies. Selective detection of TSHR stimulating auto-antibodies (TSI) was previously only possible with functional cell-based bioassays. However, more recently an automated bridge-based binding assay to more specifically measure TSI has become available. The aim of our study was to compare the third-generation automated competitive immunoassay (TBII) with the automated bridge immunoassay (TSI) in clinical practice in an academic thyroid expert center.

METHODS: A retrospective study in 356 patients with Graves' disease, Graves orbitopathy (GO), and other (thyroid) disease treated in an academic thyroid center was performed. All samples were analyzed for TBII and TSI. For both assays, sensitivity, specificity, positive predictive value (PVV), negative predictive value (NPV) and diagnostic odds ratios were calculated using different cut-offs for negativity.

RESULTS: Using the provided cut-off, the overall sensitivity appeared similar between TBII and TSI, but TSI showed higher overall specificity, PPV, NPV and diagnostic odds ratio. Using two or three times the cut-off for negativity resulted in a decrease in sensitivity, but an increase in specificity and PPV, which was most pronounced for the TBII-assay. Analysis in a subgroup of newly diagnosed treatment naïve GD/GO patients also revealed overall favorable results for the TSI-assay. Increasing the cut-off for negativity resulted in increased specificity for both assays, with similar results using two or three times the cut-off. Most patients with concordant positive results for TBII and TSI suffered from GD or GD + GO (n = 110, 95.6 %), while patients negative for both TBII and TSI mostly suffered from other (thyroid) disease (n = 143, 77.3 %). From patients with positive TBII but negative TSI only 42.1 % had GD/GO (n = 16), whereas 57.9 % (n = 22) had other (thyroid) disease. In contrast, 88.9 % of patients with positive TSI but negative TBII had GD/GO (n = 16), whereas 11.1 % (n = 2) had other (thyroid) disease.

CONCLUSION: In our academic thyroid center, the diagnostic performance of the TSI-assay outperformed the TBII-assay. Using a higher cut-off value for negativity can be helpful in assessing clinical relevance.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app