PURPOSE: End-tidal CO2 is used to monitor the ventilation status or hemodynamic efficacy during mechanical ventilation or cardiopulmonary resuscitation (CPR), and it may be affected by various factors including sodium bicarbonate administration. This study investigated changes in end-tidal CO2 after sodium bicarbonate administration.

MATERIALS AND METHODS: This single-center, prospective observational study included adult patients who received sodium bicarbonate during mechanical ventilation or CPR. End-tidal CO2 elevation was defined as an increase of ≥20% from the baseline end-tidal CO2 value. The time to initial increase (lag time, Tlag ), time to peak (Tpeak ), and duration of the end-tidal CO2 rise (Tduration ) were compared between the patients with spontaneous circulation (SC group) and those with ongoing resuscitation (CPR group).

RESULTS: Thirty-three patients, (SC group, n = 25; CPR group, n = 8), were included. Compared with the baseline value, the median values of peak end-tidal CO2 after sodium bicarbonate injection increased by 100% (from 21 to 41 mmHg) in all patients, 89.5% (from 21 to 39 mmHg) in the SC group, and 160.2% (from 15 to 41 mmHg) in the CPR group. The median Tlag was 17 s (IQR: 12-21) and the median Tpeak was 35 s (IQR: 27-52). The median Tduration was 420 s (IQR: 90-639). The median Tlag , Tpeak , and Tduration were not significantly different between the groups. Tduration was associated with the amount of sodium bicarbonate for SC group (correlation coefficient: 0.531, p = 0.006).

CONCLUSION: The administration of sodium bicarbonate may lead to a substantial increase in end-tidal CO2 for several minutes in patients with spontaneous circulation and in patients with ongoing CPR. After intravenous administration of sodium bicarbonate, the use of end-tidal CO2 pressure as a physiological indicator may be limited.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app