We have located links that may give you full text access.
The reliability of a portable steam sauna pod for the whole-body passive heating of humans.
Journal of Thermal Biology 2023 October 32
INTRODUCTION: Passive heating is receiving increasing attention within human performance and health contexts. A low-cost, portable steam sauna pod may offer an additional tool for those seeking to manipulate physiological (cardiovascular, thermoregulatory and sudomotor) and perceptual responses for improving sporting or health profiles. This study aimed to 1) report the different levels of heat stress and determine the pods' inter-unit reliability, and 2) quantify the reliability of physiological and perceptual responses to passive heating.
METHOD: In part 1, five pods were assessed for temperature and relative humidity (RH) every 5 min across 70 min of heating for each of the 9 settings. In part 2, twelve males (age: 24 ± 4 years) completed two 60 min trials of passive heating (3 × 20 min at 44 °C/99% RH, separated by 1 week). Heart rate (HR), rectal (Trectal ) and tympanic temperature (Ttympanic ) were recorded every 5 min, thermal comfort (Tcomfort ) and sensation (Tsensation ) every 10 min, mean arterial pressure (MAP) at each break period and sweat rate (SR) after exiting the pod.
RESULTS: In part 1, setting 9 provided the highest temperature (44.3 ± 0.2 °C) and longest time RH remained stable at 99% (51±7 min). Inter-unit reliability data demonstrated agreement between pods for settings 5-9 (intra-class correlation [ICC] >0.9), but not for settings 1-4 (ICC <0.9). In part 2, between-visits, high correlations, and low typical error of measurement (TEM) and coefficient of variation (CV) were found for Trectal , HR, MAP, SR, and Tcomfort , but not for Ttympanic or Tsensation . A peak Trectal of 38.09 ± 0.30 °C, HR of 124 ± 15 b min-1 and a sweat loss of 0.73 ± 0.33 L were reported. No between-visit differences (p > 0.05) were observed for Trectal , Ttympanic , Tsensation or Tcomfort , however HR (+3 b.min-1 ) and MAP (+4 mmHg) were greater in visit 1 vs. 2 (p < 0.05).
CONCLUSION: Portable steam sauna pods generate reliable heat stress between-units. The highest setting (44 °C/99% RH) also provides reliable but modest adjustments in physiological and perceptual responses.
METHOD: In part 1, five pods were assessed for temperature and relative humidity (RH) every 5 min across 70 min of heating for each of the 9 settings. In part 2, twelve males (age: 24 ± 4 years) completed two 60 min trials of passive heating (3 × 20 min at 44 °C/99% RH, separated by 1 week). Heart rate (HR), rectal (Trectal ) and tympanic temperature (Ttympanic ) were recorded every 5 min, thermal comfort (Tcomfort ) and sensation (Tsensation ) every 10 min, mean arterial pressure (MAP) at each break period and sweat rate (SR) after exiting the pod.
RESULTS: In part 1, setting 9 provided the highest temperature (44.3 ± 0.2 °C) and longest time RH remained stable at 99% (51±7 min). Inter-unit reliability data demonstrated agreement between pods for settings 5-9 (intra-class correlation [ICC] >0.9), but not for settings 1-4 (ICC <0.9). In part 2, between-visits, high correlations, and low typical error of measurement (TEM) and coefficient of variation (CV) were found for Trectal , HR, MAP, SR, and Tcomfort , but not for Ttympanic or Tsensation . A peak Trectal of 38.09 ± 0.30 °C, HR of 124 ± 15 b min-1 and a sweat loss of 0.73 ± 0.33 L were reported. No between-visit differences (p > 0.05) were observed for Trectal , Ttympanic , Tsensation or Tcomfort , however HR (+3 b.min-1 ) and MAP (+4 mmHg) were greater in visit 1 vs. 2 (p < 0.05).
CONCLUSION: Portable steam sauna pods generate reliable heat stress between-units. The highest setting (44 °C/99% RH) also provides reliable but modest adjustments in physiological and perceptual responses.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app