Add like
Add dislike
Add to saved papers

Successful Removal of a Fractured Desilets-Hoffman Sheath in a Patient With a Loop Arteriovenous Graft: Balloon-Supported Retrieval Technique.

INTRODUCTION: While a Desilets-Hoffman sheath rarely fractures, when it does, the presence of an intravenous foreign body can cause various complications.

CASE PRESENTATION: A 74-year-old woman receiving hemodialysis for end-stage renal disease via a left forearm arteriovenous graft (AVG) was referred to the interventional radiology department following thrombotic occlusion of the AVG. A corrective procedure was initiated, and the 7F Desilets-Hoffman sheath fractured after the purse-string suture. A .035-inch guidewire was passed through the fractured sheath, and a 3.0-mm x 60-mm balloon catheter was inflated, allowing for the successful removal of the sheath fragment without complications.

CONCLUSION: The fractured Desilets-Hoffman sheath was successfully removed in a patient with a loop arteriovenous graft using balloon-supported retrieval technique.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app