Add like
Add dislike
Add to saved papers

Effectiveness and safety of prophylactic abdominal aortic balloon occlusion for patients with type III caesarean scar pregnancy: a prospective cohort study.

BACKGROUND: Caesarean scar pregnancy (CSP) is a special type of ectopic pregnancy with a high risk of massive haemorrhage. Few studies have focused on the efficacy of prophylactic abdominal aortic balloon occlusion as a minimally invasive method in caesarean section. This study aimed to evaluate the effectiveness and safety of prophylactic abdominal aortic balloon occlusion for patients with type III CSP.

METHODS: This was a prospective cohort study. Patients with type III CSP in the First Affiliated Hospital of Zhengzhou University from January 2020 to June 2022 were enrolled. Eligible patients received prophylactic abdominal aortic balloon occlusion (defined as the AABO group) or uterine artery embolization (defined as the UAE group) before laparoscopic surgery. Clinical outcomes included intraoperative blood loss, body surface radiation dose, hospitalization expenses, and time to serum β-hCG normalization, and safety were also assessed.

RESULTS: A total of 68 patients met the criteria for the study, of whom 34 patients were in the AABO group and 34 patients were in the UAE group. The median intraoperative blood loss in the AABO and UAE groups was 17.5 (interquartile ranges [IQR]: 10, 45) and 10 (IQR: 6.25, 20) mL, respectively (P = 0.264). The body surface radiation dose of the AABO group was much lower than that of the UAE group (5.22 ± 0.44 vs. 1441.85 ± 11.59 mGy, P < 0.001). The AABO group also had lower hospitalization expenses than the UAE group (2.42 ± 0.51 vs. 3.42 ± 0.85 *10^5 yuan, P < 0.001). The average time to serum β-hCG normalization in the AABO group was 28.9 ± 3.21 d, which was similar to that in the UAE group (30.3 ± 3.72 d, P = 0.099). In addition, the incidence of adverse events in the AABO group was lower than that in the UAE group (5.9% vs. 58.8%, P < 0.001).

CONCLUSION: Prophylactic AABO was equally as effective as UAE in patients with type III CSP but was safer than UAE during and after the operation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app