Add like
Add dislike
Add to saved papers

Facile Modification of Medical-Grade Silicone for Antimicrobial Effectiveness and Biocompatibility: A Potential Therapeutic Strategy against Bacterial Biofilms.

A one-step modification of biomedical silicone tubing with N , N -dimethyltetradecylamine, C14, results in a composition designated WinGard-1 (WG-1, 1.1 wt % C14). A surface-active silicon-amine phase (SAP) is proposed to account for increased wettability and increased surface charge. To understand the mechanism of antimicrobial effectiveness, several procedures were employed to detect whether C14 leaching occurred. An immersion-growth (IG) test was developed that required knowing the bacterial Minimum Inhibitory Concentrations (MICs) and Minimum Biocidal Concentrations (MBCs). The C14 MIC and MBC for Gm- uropathogenic E. coli (UPEC), commonly associated with catheter-associated urinary tract infections (CAUTI), were 10 and 20 μg/mL, respectively. After prior immersion of WG-1 silicone segments in a growth medium from 1 to 28 d, the IG test for the medium showed normal growth for UPEC over 24 h, indicating that the concentration of C14 must be less than the MIC, 10 μg/mL. GC-MS and studies of the medium inside and outside a dialysis bag containing WG-1 silicone segments supported de minimis leaching. Consequently, a 5 log UPEC reduction (99.999% kill) in 24 h using the shake flask test (ASTM E2149) cannot be due to leaching and is ascribed to contact kill. Interestingly, although the MBC was greater than 100 μg/mL for Pseudomonas aeruginosa , WG-1 silicone affected an 80% reduction via a 24 h shake flask test. For other bacteria and Candida albicans , greater than 99.9% shake flask kill may be understood by proposing increased wettability and concentration of charge illustrated in the TOC. De minimis leaching places WG-1 silicone at an advantage over conventional anti-infectives that rely on leaching of an antibiotic or heavy metals such as silver. The facile process for preparation of WG-1 silicone combined with biocidal effectiveness comprises progress toward the goals of device designation from the FDA for WG-1 and clearance.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app