Add like
Add dislike
Add to saved papers

Catastrophic Mid-Flexion Instability After Avulsion Fractures of the Articular Capsule of the Femur and Tibia in a Patient With Posterior-Stabilized Total Knee Arthroplasty: A Case Report.

Curēus 2023 August
Mid-flexion instability can be caused by patient-related, implant-related, or technique-specific factors and impairs the activities of daily living after total knee arthroplasty (TKA). In this study, we report a rare case of a patient with severe mid-flexion instability following tibial and femoral avulsion fractures after posterior-stabilized (PS) TKA for knee osteoarthritis. An 82-year-old female with bilateral knee osteoarthritis underwent staged bilateral TKA with a posterior-stabilized prosthesis. The course of the early postoperative period was good, and the patient was able to walk independently with a cane. Two months postoperatively, the patient fell and then experienced left knee pain and instability in the mid-flexion range. Radiographic images showed avulsion fractures of the articular capsule of the femur and tibia, and fluoroscopic examination showed severe posterior subluxation of the tibia between 40° and 60° of flexion. Conservative treatment with a functional knee brace and quadriceps training was initiated due to the patient's hesitation to undergo a second surgery; however, no improvement was observed. Eventually, revision surgery was planned three months after the fall incident (five months after the left primary TKA). At revision surgery, osteosynthesis of the tibial avulsion fracture and thickening of the PS insert did not sufficiently stabilize the instability, and revision TKA with a rotating-hinge prosthesis was needed. The postoperative course was uneventful, and she was able to walk with a cane within two weeks after revision TKA with no complaints of instability. Two years postoperatively, the patient recovered well and had no recurrence of instability, pain, or dysfunction. This case report shows that loss of support by the joint capsules due to avulsion fractures may cause significant anteroposterior instability in the mid-flexion position after posterior-stabilized TKA. In such a case, conservative treatment failed, and the revision of the rotating-hinge prosthesis provided stability and good improvement.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app