We have located links that may give you full text access.
Efficacy of 1 L polyethylene glycol plus ascorbate versus 4 L polyethylene glycol in split-dose for colonoscopy cleansing in out and inpatient: A multicentre, randomized trial (OVER 2019).
Digestive and Liver Disease 2023 August 12
BACKGROUND AND AIMS: Adequate bowel cleansing is essential for colonoscopy quality. A novel 1 L polyethylene glycol plus ascorbate (1 L PEG+ASC) solution has been recently introduced. Nevertheless, the efficacy of 1 L PEG+ASC as compared to that of high-volume bowel preparation in both inpatients and outpatients is still unclear.
PATIENTS AND METHODS: This single-blinded, non-inferiority study randomized patients undergoing colonoscopy to receive split-dose 1 L PEG+ASC or 4 L PEG. The primary endpoint was the overall cleansing success. Secondary endpoints were excellent cleansing and high-quality cleansing of the right colon, as well as lesions detection rate, patient compliance, tolerability and safety.
RESULTS: Overall, 478 patients were randomized to 1 L PEG+ASC (N = 236) or 4 L PEG (N = 242). The 1 L PEG+ASC showed higher cleansing success rate (91.8% vs 83.6%; P=0.01) and a high-quality cleansing of the right colon (52.3% and 38.5%; P=0.004) compared to 4 L PEG. Moreover, 1 L PEG+ASC achieved a higher cleansing success in out-patients (96.3%% vs 88.6%; P=0.018), and a similar success rate in the in-patients (84.7% vs 76.7%; P=0.18). Adenoma detection rate, tolerability and incidence of adverse events were comparable between preparations.
CONCLUSIONS: The 1 L PEG+ASC showed higher efficacy in achieving adequate colon cleansing compared with 4 L PEG, particularly in the right colon. No differences in the tolerability and safety were detected.
PATIENTS AND METHODS: This single-blinded, non-inferiority study randomized patients undergoing colonoscopy to receive split-dose 1 L PEG+ASC or 4 L PEG. The primary endpoint was the overall cleansing success. Secondary endpoints were excellent cleansing and high-quality cleansing of the right colon, as well as lesions detection rate, patient compliance, tolerability and safety.
RESULTS: Overall, 478 patients were randomized to 1 L PEG+ASC (N = 236) or 4 L PEG (N = 242). The 1 L PEG+ASC showed higher cleansing success rate (91.8% vs 83.6%; P=0.01) and a high-quality cleansing of the right colon (52.3% and 38.5%; P=0.004) compared to 4 L PEG. Moreover, 1 L PEG+ASC achieved a higher cleansing success in out-patients (96.3%% vs 88.6%; P=0.018), and a similar success rate in the in-patients (84.7% vs 76.7%; P=0.18). Adenoma detection rate, tolerability and incidence of adverse events were comparable between preparations.
CONCLUSIONS: The 1 L PEG+ASC showed higher efficacy in achieving adequate colon cleansing compared with 4 L PEG, particularly in the right colon. No differences in the tolerability and safety were detected.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app