Pregnancy outcomes with a copper 380 mm 2 intrauterine device in place: A retrospective cohort study in Turkey, 2011-2021.

Contraception 2023 September
OBJECTIVES: To investigate pregnancy outcomes in patients with pregnancies with a copper 380 mm2 intrauterine device (IUD) in situ at conception.

STUDY DESIGN: In this retrospective study, we identified patients with pregnancies with a copper 380 mm2 IUD between 2011 and 2021 from the electronic health record system. According to their initial diagnosis, we classified the patients as having nonviable intrauterine pregnancies (IUPs), viable IUPs, or ectopic pregnancies. Among the viable IUPs, we divided the ongoing pregnancies into two subgroups as IUD-removed and IUD-retained. We compared the pregnancy loss (miscarriage before 22 weeks) rates and adverse pregnancy outcomes (at least one of preterm birth, preterm premature rupture of membranes, chorioamnionitis, placental abruption, or postpartum hemorrhage) of IUD-removed and IUD-retained pregnancies.

RESULTS: We identified a total of 246 patients with pregnancies with an IUD. We excluded six (2.4%) patients without follow-up data and seven (2.8%) patients with levonorgestrel-IUD and included the remaining 233 (44 [18.9%] ectopic pregnancy, 31 [13.3%] nonviable IUP, and 158 [67.5%] viable IUP) patients. Among the 158 women with viable IUP, 21 (13.3%) underwent abortion, leaving 137 (86.7%) who elected to continue the pregnancy. A total of 54 (39.4%) patients with ongoing pregnancy had the IUD removed. We found a lower rate of pregnancy loss among those who underwent removal (18/54 [33.3%]) compared to those with a retained IUD (51/83 [61.4%], p < 0.001). After accounting for pregnancy loss, adverse pregnancy outcomes remained increased in the IUD-retained group (17/32 [53.1%]) compared to the IUD-removed group (10/36 [27.8%], p = 0.03).

CONCLUSIONS: Pregnancy in the setting of a copper 380 mm2 IUD is high risk. Our results demonstrate that pregnancy outcomes improve by removal of the copper 380 mm2 IUD.

IMPLICATIONS: Prior studies have suggested that the removal of the IUD improves outcomes, but all have limitations. Our results from a very large series with care in a single institution provide contemporary evidence to support copper 380 mm2 IUD removal to reduce the risk of both early pregnancy loss and later adverse outcomes.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app