Add like
Add dislike
Add to saved papers

Simultaneous Analysis and Efficient Separation of Anabolic Androgenic Steroids in Dietary Supplement by a Validated HPTLC Method.

BACKGROUND: Using sports supplements is common among athletes. The presence of anabolic steroids in sports supplements as a hormonal contaminant can increase production efficiency. Since anabolic steroids cause health problems and result in positive doping tests in athletes, it is important to investigate their presence in the supplement preparations consumed by athletes.

OBJECTIVES: This paper aims to simultaneously determine ten anabolic steroids by high-performance thin-layer chromatography (HPTLC) method in sports supplements.

METHODS: Chromatographic analysis was conducted on glass silica gel 60F254 plates. The extracts loaded on silica gel plates are subjected to programed multiple development (PMD) to separate anabolic androgenic steroids (AASs). Densitometric scanning is carried out at the wavelength of 245 and 366nm. The method was validated according to the ICH guidelines.

RESULTS: Spots at retardation factor (Rf) 0.72 (elution system 1), 0.4 (elution system 1), 0.29 (elution system 2), 0.25 (elution system 2), 0.1 (elution system 1), 0.65 (elution system 2), 0.59 (elution system 1), 0.44 (elution system 1), 0.8 (elution system 3), and 0.82 (elution system 3) values were recognized as 19-nor androstenedione, 19-nortestosterone, methyl testosterone, clostebol, stanozolol, trenbolone enanthate, oxymetholone, oxandrolone, testosterone enanthate, and nandrolone decanoate, respectively. The linear ranges were 25 - 250 μg/mL for oxymetholone, 7 - 50 μg/mL for 19-nor androstenedione, 19-nortestosterone, and oxandrolone, and 3 - 20 μg/mL for methyl testosterone, clostebol, stanozolol, trenbolone enanthate, testosterone enanthate, and nandrolone decanoate. The developed method is validated by acceptable precision (CV < 20%) and good accuracy (94% < R < 114%). The value of limit of detection (LOD) for all derivatives was in the range of 0.02 - 0.16 μg/spot (20-160 μg/g of supplement), while limit of quantitation (LOQ) was found to be in the range of 0.06 - 0.5 μg/spot (60 - 500 μg/g of supplement). Fifty sports supplement samples as real sample were collected and analyzed. None of the samples screened positive using the HPTLC method.

CONCLUSIONS: In the present study, the fast, cheap, and simple HPTLC method could be used for the multi-residue analysis of ten anabolic androgenic steroids in sports supplements.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app