Reduction of anti-A and anti-B isoagglutinin titers of group O whole blood units employing an ABO antibody immune adsorption column.
Transfusion and Apheresis Science 2023 March 6
BACKGROUND: Massive hemorrhage is a leading cause of death from trauma. There is growing interest in group O whole blood transfusions to mitigate coagulopathy and hemorrhagic shock. Insufficient availability of low-titer group O whole blood is a barrier to routine use. We tested the efficacy of the Glycosorb® ABO immunoadsorption column to reduce anti-A/B titers in group O whole blood.
METHODS: Six group O whole blood units were collected from healthy volunteers, and centrifuged to separate platelet poor plasma. Platelet-poor plasma was filtered through a Glycosorb® ABO antibody immunoabsorption column, then reconstituted to prepare post-filtration whole blood. Anti-A/B titers, CBC, free hemoglobin, and thromboelastography (TEG) assays were performed on pre-and post-filtration whole blood.
RESULTS: Mean( ± SEM) anti-A (224 ± 65 pre vs 13 ± 4 post) and anti-B (138 ± 38 pre vs 11 ± 4 post) titers were significantly reduced (p = 0.004) in post-filtration whole blood. No significant changes were detected in CBC, free hemoglobin, and TEG parameters on day 0. Free hemoglobin increased throughout storage (48 mg/dl ± 24 Day 0 vs 73 ± 35 Day 7 vs 96 ± 44 Day 14; p = 0.14).
CONCLUSIONS: The Glycosorb® ABO column can significantly reduce anti-A/B isoagglutinin titers of group O whole blood units. Glycosorb® ABO could be employed to provide whole blood with lower risk of hemolysis and other consequences of infusing ABO incompatible plasma. Preparation of group O whole blood with substantially reduced anti-A/B would also increase the supply of low-titer group O whole blood for transfusion.
METHODS: Six group O whole blood units were collected from healthy volunteers, and centrifuged to separate platelet poor plasma. Platelet-poor plasma was filtered through a Glycosorb® ABO antibody immunoabsorption column, then reconstituted to prepare post-filtration whole blood. Anti-A/B titers, CBC, free hemoglobin, and thromboelastography (TEG) assays were performed on pre-and post-filtration whole blood.
RESULTS: Mean( ± SEM) anti-A (224 ± 65 pre vs 13 ± 4 post) and anti-B (138 ± 38 pre vs 11 ± 4 post) titers were significantly reduced (p = 0.004) in post-filtration whole blood. No significant changes were detected in CBC, free hemoglobin, and TEG parameters on day 0. Free hemoglobin increased throughout storage (48 mg/dl ± 24 Day 0 vs 73 ± 35 Day 7 vs 96 ± 44 Day 14; p = 0.14).
CONCLUSIONS: The Glycosorb® ABO column can significantly reduce anti-A/B isoagglutinin titers of group O whole blood units. Glycosorb® ABO could be employed to provide whole blood with lower risk of hemolysis and other consequences of infusing ABO incompatible plasma. Preparation of group O whole blood with substantially reduced anti-A/B would also increase the supply of low-titer group O whole blood for transfusion.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app