We have located links that may give you full text access.
Performance of the PRISM I, PIM2, PELOD-2 and PRISM IV scoring systems in western China: a multicenter prospective study.
World Journal of Pediatrics : WJP 2022 September 14
BACKGROUND: The aim of this study was to evaluate the performance of the four scoring tools in predicting mortality in pediatric intensive care units (PICUs) in western China.
METHODS: This was a multicenter, prospective, cohort study conducted in six PICUs in western China. The performances of the scoring systems were evaluated based on both discrimination and calibration. Discrimination was assessed by calculating the area under the receiver operating characteristic curve (AUC) for each model. Calibration was measured across defined groups based on mortality risk using the Hosmer-Lemeshow goodness-of-fit test.
RESULTS: A total of 2034 patients were included in this study, of whom 127 (6.2%) died. For the entire cohort, AUCs for Pediatric Risk of Mortality Score (PRISM) I, Pediatric Index of Mortality 2 (PIM2), Pediatric Logistic Organ Dysfunction Score-2 (PELOD-2) and PRISM IV were 0.88 [95% confidence interval (CI) 0.85-0.92], 0.84 (95% CI 0.80-0.88), 0.80 (95% CI 0.75-0.85), and 0.91 (95% CI 0.88-0.94), respectively. The Hosmer-Lemeshow goodness-of-fit Chi-square value was 12.71 (P = 0.12) for PRISM I, 4.70 (P = 0.79) for PIM2, 205.98 (P < 0.001) for PELOD-2, and 7.50 (P = 0.48) for PRISM IV [degree of freedom (df) = 8]. The standardized mortality ratios obtained with the PRISM I, PIM2, PELOD-2, and PRISM IV models were 0.87 (95% CI, 0.75-1.01), 0.97 (95% CI, 0.85-1.12), 1.74 (95% CI, 1.58-1.92), and 1.05 (95% CI, 0.92-1.21), respectively.
CONCLUSIONS: PRISM IV performed best and can be used as a prediction tool in PICUs in Western China. However, PRISM IV needs to be further validated in NICUs.
METHODS: This was a multicenter, prospective, cohort study conducted in six PICUs in western China. The performances of the scoring systems were evaluated based on both discrimination and calibration. Discrimination was assessed by calculating the area under the receiver operating characteristic curve (AUC) for each model. Calibration was measured across defined groups based on mortality risk using the Hosmer-Lemeshow goodness-of-fit test.
RESULTS: A total of 2034 patients were included in this study, of whom 127 (6.2%) died. For the entire cohort, AUCs for Pediatric Risk of Mortality Score (PRISM) I, Pediatric Index of Mortality 2 (PIM2), Pediatric Logistic Organ Dysfunction Score-2 (PELOD-2) and PRISM IV were 0.88 [95% confidence interval (CI) 0.85-0.92], 0.84 (95% CI 0.80-0.88), 0.80 (95% CI 0.75-0.85), and 0.91 (95% CI 0.88-0.94), respectively. The Hosmer-Lemeshow goodness-of-fit Chi-square value was 12.71 (P = 0.12) for PRISM I, 4.70 (P = 0.79) for PIM2, 205.98 (P < 0.001) for PELOD-2, and 7.50 (P = 0.48) for PRISM IV [degree of freedom (df) = 8]. The standardized mortality ratios obtained with the PRISM I, PIM2, PELOD-2, and PRISM IV models were 0.87 (95% CI, 0.75-1.01), 0.97 (95% CI, 0.85-1.12), 1.74 (95% CI, 1.58-1.92), and 1.05 (95% CI, 0.92-1.21), respectively.
CONCLUSIONS: PRISM IV performed best and can be used as a prediction tool in PICUs in Western China. However, PRISM IV needs to be further validated in NICUs.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app