Breast Ultrasound Volume Sweep Imaging: A New Horizon in Expanding Imaging Access for Breast Cancer Detection.
Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine 2022 July 9
OBJECTIVE: The majority of people in the world lack basic access to breast diagnostic imaging resulting in delay to diagnosis of breast cancer. In this study, we tested a volume sweep imaging (VSI) ultrasound protocol for evaluation of palpable breast lumps that can be performed by operators after minimal training without prior ultrasound experience as a means to increase accessibility to breast ultrasound.
METHODS: Medical students without prior ultrasound experience were trained for less than 2 hours on the VSI breast ultrasound protocol. Patients presenting with palpable breast lumps for standard of care ultrasound examination were scanned by a trained medical student with the VSI protocol using a Butterfly iQ handheld ultrasound probe. Video clips of the VSI scan imaging were later interpreted by an attending breast imager. Results of VSI scan interpretation were compared to the same-day standard of care ultrasound examination.
RESULTS: Medical students scanned 170 palpable lumps with the VSI protocol. There was 97% sensitivity and 100% specificity for a breast mass on VSI corresponding to 97.6% agreement with standard of care (Cohen's κ = 0.95, P < .0001). There was a detection rate of 100% for all cancer presenting as a sonographic mass. High agreement for mass characteristics between VSI and standard of care was observed, including 87% agreement on Breast Imaging-Reporting and Data System assessments (Cohen's κ = 0.82, P < .0001).
CONCLUSIONS: Breast ultrasound VSI for palpable lumps offers a promising means to increase access to diagnostic imaging in underserved areas. This approach could decrease delay to diagnosis for breast cancer, potentially improving morbidity and mortality.
METHODS: Medical students without prior ultrasound experience were trained for less than 2 hours on the VSI breast ultrasound protocol. Patients presenting with palpable breast lumps for standard of care ultrasound examination were scanned by a trained medical student with the VSI protocol using a Butterfly iQ handheld ultrasound probe. Video clips of the VSI scan imaging were later interpreted by an attending breast imager. Results of VSI scan interpretation were compared to the same-day standard of care ultrasound examination.
RESULTS: Medical students scanned 170 palpable lumps with the VSI protocol. There was 97% sensitivity and 100% specificity for a breast mass on VSI corresponding to 97.6% agreement with standard of care (Cohen's κ = 0.95, P < .0001). There was a detection rate of 100% for all cancer presenting as a sonographic mass. High agreement for mass characteristics between VSI and standard of care was observed, including 87% agreement on Breast Imaging-Reporting and Data System assessments (Cohen's κ = 0.82, P < .0001).
CONCLUSIONS: Breast ultrasound VSI for palpable lumps offers a promising means to increase access to diagnostic imaging in underserved areas. This approach could decrease delay to diagnosis for breast cancer, potentially improving morbidity and mortality.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app