We have located links that may give you full text access.
Expanding the utility of the ROX index among patients with acute hypoxemic respiratory failure.
PloS One 2022
BACKGROUND: Delaying intubation in patients who fail high-flow nasal cannula (HFNC) may result in increased mortality. The ROX index has been validated to predict HFNC failure among pneumonia patients with acute hypoxemic respiratory failure (AHRF), but little information is available for non-pneumonia causes. In this study, we validate the ROX index among AHRF patients due to both pneumonia or non-pneumonia causes, focusing on early prediction.
METHODS: This was a retrospective observational study in eight Singapore intensive care units from 1 January 2015 to 30 September 2017. All patients >18 years who were treated with HFNC for AHRF were eligible and recruited. Clinical parameters and arterial blood gas values at HFNC initiation and one hour were recorded. HFNC failure was defined as requiring intubation post-HFNC initiation.
RESULTS: HFNC was used in 483 patients with 185 (38.3%) failing HFNC. Among pneumonia patients, the ROX index was most discriminatory in pneumonia patients one hour after HFNC initiation [AUC 0.71 (95% CI 0.64-0.79)], with a threshold value of <6.06 at one hour predicting HFNC failure (sensitivity 51%, specificity 80%, positive predictive value 61%, negative predictive value 73%). The discriminatory power remained moderate among pneumonia patients upon HFNC initiation [AUC 0.65 (95% CI 0.57-0.72)], non-pneumonia patients at HFNC initiation [AUC 0.62 (95% CI 0.55-0.69)] and one hour later [AUC 0.63 (95% CI 0.56-0.70)].
CONCLUSION: The ROX index demonstrated moderate discriminatory power among patients with either pneumonia or non-pneumonia-related AHRF at HFNC initiation and one hour later.
METHODS: This was a retrospective observational study in eight Singapore intensive care units from 1 January 2015 to 30 September 2017. All patients >18 years who were treated with HFNC for AHRF were eligible and recruited. Clinical parameters and arterial blood gas values at HFNC initiation and one hour were recorded. HFNC failure was defined as requiring intubation post-HFNC initiation.
RESULTS: HFNC was used in 483 patients with 185 (38.3%) failing HFNC. Among pneumonia patients, the ROX index was most discriminatory in pneumonia patients one hour after HFNC initiation [AUC 0.71 (95% CI 0.64-0.79)], with a threshold value of <6.06 at one hour predicting HFNC failure (sensitivity 51%, specificity 80%, positive predictive value 61%, negative predictive value 73%). The discriminatory power remained moderate among pneumonia patients upon HFNC initiation [AUC 0.65 (95% CI 0.57-0.72)], non-pneumonia patients at HFNC initiation [AUC 0.62 (95% CI 0.55-0.69)] and one hour later [AUC 0.63 (95% CI 0.56-0.70)].
CONCLUSION: The ROX index demonstrated moderate discriminatory power among patients with either pneumonia or non-pneumonia-related AHRF at HFNC initiation and one hour later.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app