Add like
Add dislike
Add to saved papers

Electrophysiological characteristics of non-pulmonary vein triggers excluding origins from the superior vena cava and left atrial posterior wall: Lessons from the self-reference mapping technique.

BACKGROUND: The detailed electrophysiological characteristics of atrial fibrillation (AF) initiating non-pulmonary vein (PV) triggers excluding origins from the superior vena cava (SVC) and left atrial posterior wall (LAPW) (Non-PV-SVC-LAPW triggers) remain unclear. This study aimed to clarify the detailed electrophysiological characteristics of non-PV-SVC-LAPW triggers.

METHODS: Among 446 AF ablation procedures at 2 institutions, patients with reproducible AF initiating non-PV-SVC-LAPW triggers were retrospectively enrolled. The trigger origin was mapped using the self-reference mapping technique. The following electrophysiological parameters were evaluated: the voltage during sinus rhythm and at the onset of AF at the earliest activation site, coupling interval of the trigger between the prior sinus rhythm and AF trigger, and voltage change ratio defined as the trigger voltage at the onset of AF divided by the sinus voltage.

RESULTS: Detailed electrophysiological data were obtained at 28 triggers in 21 patients. The median trigger voltage at the onset of AF was 0.16mV and median trigger coupling interval 182msec. Normal sinus voltages (≧0.5mV) were observed at 16 triggers and low voltages (<0.5mV) at 12 triggers. The voltage change ratio was significantly lower for the normal sinus voltage than low sinus voltage (0.20 vs. 0.60, p = 0.002). The trigger coupling intervals were comparable between the normal sinus voltage and low sinus voltage (170ms vs. 185ms, p = 0.353).

CONCLUSIONS: The trigger voltage at the onset of AF was low, regardless of whether the sinus voltage of the trigger was preserved or low.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app