Add like
Add dislike
Add to saved papers

Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging.

Head motion during brain PET imaging can cause significant degradation of the quality of the reconstructed image, leading to reduced diagnostic value and inaccurate quantitation. A fully data-driven motion correction approach was recently demonstrated to produce highly accurate motion estimates (< 1 mm) with high temporal resolution (≥ 1 Hz), which can then be used for a motion corrected reconstruction. This can be applied retrospectively with no impact on the clinical image acquisition protocol. We present a reader-based evaluation and an atlas-based quantitative analysis of this motion correction approach within a clinical cohort. Methods: Clinical patient data were collected over 2019-2020 and processed retrospectively. Motion estimation was performed using image-based registration on reconstructions of ultra-short frames (0.6-1.8 s), after which fully motion corrected list-mode reconstructions were performed. Two readers graded the motion corrected and uncorrected reconstructions. An atlas-based quantitative analysis was performed. Paired Wilcoxon tests were used to test for significant differences in the reader scores and standard uptake values between the reconstructions. Levene's test was used to test whether motion correction had a greater impact on the quantitation in the presence of motion than when low motion was observed. Results: 50 standard clinical 18 F-fluorodeoxyglucose brain PET data sets (age range 13-83 years, mean age ± standard deviation 59 ± 20 years, 27 women) from 3 scanners were collected. The reader study showed a significantly different, diagnostically relevant improvement by motion correction for cases where motion was present ( P = 0.02) and no impact in low motion cases. 8% of all data sets improved from diagnostically "unacceptable" to "acceptable". The atlas-based analysis demonstrated a significant difference between the motion corrected and uncorrected reconstructions in cases of high motion for 7 of 8 ROIs ( P < 0.05). Conclusion: The proposed data-driven motion estimation and correction approach demonstrated a clinically significant impact on brain PET image reconstruction.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app