Biomechanical Performance of Charcot-Specific Implants.

Over the past 2 decades, an increased number of diabetic Charcot neuroarthropathy reconstructions have been performed. Despite advances in implant technology, arthrodesis complication rates remain high. This study examined the biomechanical properties (4-point bending, cantilever bending, and thread pullout resistance) of intramedullary implants designed for midfoot reconstruction. Large implants included A1 (7.4 mm cannulated stainless steel beam), B1 (6.5 mm solid titanium bolt), and C1 (7.0 mm cannulated titanium beam). Smaller implants included A2 (5.4 mm cannulated stainless steel beam) and C2 (5.0 mm solid titanium bolt). Four-point bending testing compared flexural properties of the body of the implants. Cantilever-bending testing was performed with the maximum bending moment being applied off the main thread of the implant to assess the thread portion. Thread pullout strength was tested by fixing the implants to a Sawbone block on a platform, and the distal portion of the implant in a clamp connected to loading actuator. Implant A1 demonstrated higher stiffness, force to failure, and fatigue compared to implants B1 and C1 (p < .05). Pullout strength of implant A1 was higher than implant B1 (p < .05). Thread fatigue strength of implant A1 was higher than implant C1 (p < .05). Implant A2 demonstrated higher stiffness, force to failure, tip fatigue strength, and thread pullout strength compared to implant C2 (p < .05), while implant C2 demonstrated higher body fatigue failure than implant A2 (p < .05). Alteration of beam/bolt parameters influences the biomechanical performance of implants used in Charcot reconstruction. Greater stiffness resists deformation, providing improved stability. Greater static failure load and fatigue limit improves the implant's ability to withstand higher and repetitive loads before failing This study should stimulate further clinical research to determine if these biomechanical properties translate into reduced implant failure rates and improved clinical outcomes in patients with diabetic Charcot neuroarthropathy.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app