Tablet and web-based audiometry to screen for hearing loss in adults with cystic fibrosis.

Thorax 2020 August
INTRODUCTION: Individuals with chronic lung disease (eg, cystic fibrosis (CF)) often receive antimicrobial therapy including aminoglycosides resulting in ototoxicity. Extended high-frequency audiometry has increased sensitivity for ototoxicity detection, but diagnostic audiometry in a sound-booth is costly, time-consuming and requires a trained audiologist. This cross-sectional study analysed tablet-based audiometry (Shoebox MD) performed by non-audiologists in an outpatient setting, alongside home web-based audiometry (3D Tune-In) to screen for hearing loss in adults with CF.

METHODS: Hearing was analysed in 126 CF adults using validated questionnaires, a web self-hearing test (0.5 to 4 kHz), tablet (0.25 to 12 kHz) and sound-booth audiometry (0.25 to 12 kHz). A threshold of ≥25 dB hearing loss at ≥1 audiometric frequency was considered abnormal. Demographics and mitochondrial DNA sequencing were used to analyse risk factors, and accuracy and usability of hearing tests determined.

RESULTS: Prevalence of hearing loss within any frequency band tested was 48%. Multivariate analysis showed age (OR 1.127; (95% CI: 1.07 to 1.18; p value<0.0001) per year older) and total intravenous antibiotic days over 10 years (OR 1.006; (95% CI: 1.002 to 1.010; p value=0.004) per further intravenous day) were significantly associated with increased risk of hearing loss. Tablet audiometry had good usability, was 93% sensitive, 88% specific with 94% negative predictive value to screen for hearing loss compared with web self-test audiometry and questionnaires which had poor sensitivity (17% and 13%, respectively). Intraclass correlation (ICC) of tablet versus sound-booth audiometry showed high correlation (ICC >0.9) at all frequencies ≥4 kHz.

CONCLUSIONS: Adults with CF have a high prevalence of drug-related hearing loss and tablet-based audiometry can be a practical, accurate screening tool within integrated ototoxicity monitoring programmes for early detection.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app