Comparative Study
Journal Article
Observational Study
Add like
Add dislike
Add to saved papers

Comparison of alteplase and urokinase for pharmacomechanical thrombolysis of clotted hemodialysis access.

BACKGROUND: Percutaneous pharmacomechanical thrombolysis is increasingly used to salvage thrombosed hemodialysis access. We aim to evaluate the effectiveness of alteplase compared to urokinase in percutaneous pharmacomechanical thrombolysis clotted access.

METHODS: Records of patients who underwent pharmacomechanical thrombolysis at Interventional Nephrology Suite in a tertiary teaching hospital from 1 January 2016 to 31 December 2016 were reviewed. Technical and clinical success rates, thrombosis-free and cumulative survivals, procedure time, and radiation dose imparted to patients were compared for pharmacomechanical thrombolysis with urokinase versus alteplase.

RESULTS: A total of 122 incident patients underwent pharmacothrombolysis (n = 53 for urokinase, n = 69 for alteplase) during the study period. The mean dose of urokinase and alteplase used was 176,897 ± 73,418 units and 3.7 ± 0.8 mg, respectively. Pharmacomechnical thrombolysis using urokinase versus alteplase has similar technical success rate (98.1% vs 97.1%, p = 0.599), clinical success rate (88.7% vs 97.1%, p = 0.068), complication rate (9.4% vs 13.0%, p = 0.373), and primary patency rates at 3 months (57.1% vs 70.1%, p = 0.106). Thrombosis-free survivals of the vascular access were 113.2 (35.3, 196) days versus 122 (84, 239) days (p = 0.168). Cumulative survivals were 239 (116, 320) vs 213 (110.5, 316.5) days (p = 0.801). Procedure time, fluoroscopy time, skin dose, and dose were significantly lower for pharmacomechanical thrombolysis using alteplase compared to urokinase (p = 0.045, p < 0.0001, p = 0.006, p = 0.001, respectively). Stenting was found to be associated with successful dialysis following thrombolysis on univariate analysis (odds ratio: 9.167, 95% confidence interval: 1.391-19.846, p = 0.021), although this was no longer significant in multivariate analysis (p = 0.078).

CONCLUSION: Alteplase is an effective and safe alternative to urokinase for pharmacomechanical thrombolysis of clotted vascular access.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app