Insertion depth of nasotracheal tubes sized to fit the nostril: an observational study.
Journal of International Medical Research 2018 December 17
OBJECTIVE: Nasotracheal (NT) intubation is commonly applied during head and neck surgery. However, improper tube size and depth may cause complications. In the current study, we investigated whether NT tubes are being appropriately used in terms of size and depth in adult patients.
METHODS: Nares were sized in 40 patients using standard nasopharyngeal airways (6.0-8.0) before elective surgery under general anesthesia. The largest sized airway that passed easily into the nasopharynx without resistance was considered as a proper size. Using a fiberoptic scope, the distances from the nares to the vocal cords and the nares to the carina were measured. Rates of proper NT tube positioning were calculated with regard to the cuff and distal tip.
RESULTS: The most frequent sizes of properly fitted NT tubes were 6.5 and 6.0 in male and female patients, respectively. Positioning of the cuff and distal tip was only appropriate when using a properly sized tube in 26% and 47% of male and female patients, respectively.
CONCLUSION: Care should be taken to determine the insertion depth after placing an NT tube that has been sized to fit the nostril. Moreover, NT tubes of the same diameter may be required in various lengths. Trial registration: Registered at ClinicalTrial.gov; https://clinicaltrials.gov/ct2/show/NCT02876913 ; Registration number NCT02876913.
METHODS: Nares were sized in 40 patients using standard nasopharyngeal airways (6.0-8.0) before elective surgery under general anesthesia. The largest sized airway that passed easily into the nasopharynx without resistance was considered as a proper size. Using a fiberoptic scope, the distances from the nares to the vocal cords and the nares to the carina were measured. Rates of proper NT tube positioning were calculated with regard to the cuff and distal tip.
RESULTS: The most frequent sizes of properly fitted NT tubes were 6.5 and 6.0 in male and female patients, respectively. Positioning of the cuff and distal tip was only appropriate when using a properly sized tube in 26% and 47% of male and female patients, respectively.
CONCLUSION: Care should be taken to determine the insertion depth after placing an NT tube that has been sized to fit the nostril. Moreover, NT tubes of the same diameter may be required in various lengths. Trial registration: Registered at ClinicalTrial.gov; https://clinicaltrials.gov/ct2/show/NCT02876913 ; Registration number NCT02876913.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app