Performance of compressed sensing-based iterative reconstruction for single-photon emission computed tomography from undersampled projection data: a simulation study in 123I-N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl)nortropane imaging.

OBJECTIVE: The aim of this study was to investigate the efficacy of compressed sensing (CS)-based iterative reconstruction (CS-IR) from undersampled projection data in I-N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl)nortropane single-photon emission computed tomography (SPECT).

MATERIALS AND METHODS: We used the cylinder/sphere and the striatal digital phantom models. The number of projections was set at 120, 90, 60, 40, and 30 projections. SPECT images were reconstructed using filtered back-projection (FBP), maximum likelihood-expectation maximization (ML-EM), and CS-IR. The total-variation transform with local image gradient in L1-norm was adopted in our CS algorithm. The efficacy of CS-IR was examined in terms of the spatial resolution, recovery coefficient, aspect ratio (ASR), activity concentration linearity, percent coefficient of variation (%CV), and specific binding ratio.

RESULTS: As the number of projections decreased, the following results were observed. No differences of the spatial resolution and activity concentration linearity were observed between reconstruction methods. However, ASR for FBP slightly increased in contrast to ML-EM and CS-IR for which ASR remained constant. There were not any clear differences between recovery coefficients obtained from each reconstruction. The %CV obtained by CS-IR was significantly superior to that obtained by other reconstructions at all number of projections: for example, the %CV obtained by 60 projection CS-IR was equivalent to that obtained by 120 projection FBP and ML-EM. The specific binding ratio did not change with the number of projections, and there were no significant differences between FBP, ML-EM, and CS-IR.

CONCLUSION: We have demonstrated that CS-IR with decreased number of projections can provide a good image quality compared with commonly used SPECT reconstruction methods. This CS could help to reduce overall acquisition time in I-N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl)nortropane SPECT, particularly.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app