Effects of low-dose energy spectrum scanning combined with adaptive statistical iterative reconstruction on the quality of imaging in Budd-Chiari syndrome.

OBJECTIVE: To assess the quality and diagnostic accuracy of monochromatic images combined with adaptive statistical iterative reconstruction (ASIR) performed via spectral computed tomography (CT) in patients with Budd-Chiari syndrome (BCS).

METHODS: Sixty-two patients with BCS underwent pectral CT with upper abdominal two-phase contrast-enhanced scanning to generate a 60keV monochromatic energy level combined with ASIR (ranging from 0% -100%) during the portal venous phase (PVP) and the hepatic venous phase (HVP). One-way ANOVA was used to compare vessel-to-liver contrast-to-noise ratio (CNR) for the portal vein (PV), hepatic vein (HV), and inferior vena cava (IVC). Subjective evaluations of the images in the three groups were conducted by image quality assessors and compared via Kruskal-Wallis H test.

RESULTS: The CNR values of the PV trunk, HV, IVC, liver parenchyma and pancreas were within ASIR (ranging from 0% - 100%) weight, and the difference were statistically significant (p <0.05). The highest overall image score was distributed at 50% ASIR weight value. Higher CNR values of HV, hepatic parenchyma and pancreas were obtained in the IVC type than in mixed and HV types (respective p values = 0.035, 0.019 and 0.042). Higher CNR values of the IVC were obtained in the HV type than in mixed and IVC types (p = 0.032). The CNR value of the IVC in the mixed type was less than that of the HV type (p = 0.028). The CNR values of the HV and liver parenchyma in mixed type were lower than those of the IVC type (p = 0.016 and 0.038, respectively). The CNR value of pancreas in IVC type was higher than that of the HV type (p = 0.037). The diagnostic value of CNR in patients with the IVC type was higher than that in patients with mixed and HV type, while the diagnostic value of CNR was found to be the lowest for the HV type (p = 0.043).

CONCLUSION: A monochromatic energy level of 60 keV with 50% ASIR can significantly improve image quality in cases of BCS.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app