Add like
Add dislike
Add to saved papers

Validation and Cross-Reactivity Data for Fentanyl Analogs With the Immunalysis Fentanyl ELISA.

Every year new fentanyl analog compounds, or fentanyls, appear on the drug scene. Development of immunoassays dedicated for screening individual molecules is challenging due to the short-lived presence of these compounds on the recreational drug market. Therefore, we investigated the detecting capabilities of the immunalysis fentanyl direct enzyme-linked immunosorbent assay (ELISA) kit against fentanyl in whole blood, and determined the cross-reactivity of nine fentanyl analogs (2-fluorofentanyl, acetylfentanyl, acrylfentanyl, carfentanil, cyclopropylfentanyl, tetrahydrofuranylfentanyl, furanylfentanyl, ocfentanil, valerylfentanyl) to confirm its validity for the general screening of fentanyls. Immunalysis ELISA assay was used to test whole blood samples fortified with fentanyl on a TECAN Freedom EVOlyzer platform, according to manufacturer specifications. The kit successfully was validated for fentanyl screening with a cutoff set at 0.5 ng/mL, and all tested analogs, with the exclusion of carfentanil, were detected. The lowest cross-reactivity with the kit was obtained with furanylfentanyl (20% ± 1, 95% confidence intervals (CI)) and 4-fluoroisobutyrfentanyl (25% ± 1, 95% CI), while the highest was recorded using acetylfentanyl (99% ± 11, 95% CI) and acrylfentanyl (94% ± 10, 95% CI). Post-mortem samples containing fentanyl, acrylfentanyl, cyclopropylfentanyl, THF-fentanyl and 4-fluoroisobutyrfentanyl were screened, and sensitivity and specificity of each analog were calculated. Positive screening results were generated by all post-mortem cases containing fentanyl (n = 14), acrylfentanyl (n = 11), cyclopropylfentanyl (n = 14), tetrahydrofuranylfentanyl (n = 13) and 4-fluoroisobutyrfentanyl (n = 10). Concentration of post-mortem fentanyl samples ranged from 0.5 ng/mL (cutoff) to 230 ng/mL, while the range for analogs was 3.4-36 ng/mL (cyclopentylfentanyl), 0.76-370 ng/mL (4-fluoroisobutyrfentanyl), 0.02-12 ng/mL (acrylfentanyl) and 2-26 ng/mL (tetrahydrofuranylfentanyl). The immunalysis fentanyl direct ELISA kit was successfully validated and showed significant cross-reactivity for all tested fentanyls, except carfentanil, making it a suitable technique for fentanyl and fentanyl analogs screening.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app