We have located links that may give you full text access.
Journal Article
Meta-Analysis
Review
The accuracy of magnifying narrow band imaging (ME-NBI) in distinguishing between cancerous and noncancerous gastric lesions: A meta-analysis.
Medicine (Baltimore) 2018 March
BACKGROUND: Previous clinical trials have demonstrated the diagnostic accuracy of magnifying narrow-band (ME-NBI) for gastric cancerous lesions, but the results are inconsistent. The purpose of this meta-analysis is to investigate the accuracy of ME-NBI in distinguishing between cancerous and noncancerous gastric lesions.
METHODS: Systematic literature searches were conducted until October 2016 in PubMed, Embase by 2 independent reviewers. Meta-analysis was performed to calculate the pooled sensitivity, specificity. Two authors independently evaluated studies for inclusion, rated methodological quality, and abstracted relevant data. Meta-analytic method was used to construct summary receiver operating characteristic curves, and pooled sensitivity, specificity were calculated.
RESULTS: Nine studies enrolling 5398 lesions were included. The pooled sensitivity, specificity were 88% (95% confidence interval [CI]: 78-93%), 96% (95% CI: 91-98%), respectively. The area under the curve (AUC) was 0.97. There was a large heterogeneity between the included studies. Studies with lesions ≤ 10 mm still had a high pooled sensitivity of 81% (95% CI: 73-90%) and specificity of 97% (95% CI: 95-100%). Studies which analyzed resected specimens had a sensitivity of 91% (95 CI: 82-99%) and specificity of 88% (95% CI: 83-94%), and studies which analyzed biopsied specimens had a sensitivity of 85% (95 CI: 74-96%) and specificity of 99% (95% CI: 98-99%).
CONCLUSIONS: ME-NBI is highly accurate and consistent to distinguish between gastric cancerous and noncancerous lesions.
METHODS: Systematic literature searches were conducted until October 2016 in PubMed, Embase by 2 independent reviewers. Meta-analysis was performed to calculate the pooled sensitivity, specificity. Two authors independently evaluated studies for inclusion, rated methodological quality, and abstracted relevant data. Meta-analytic method was used to construct summary receiver operating characteristic curves, and pooled sensitivity, specificity were calculated.
RESULTS: Nine studies enrolling 5398 lesions were included. The pooled sensitivity, specificity were 88% (95% confidence interval [CI]: 78-93%), 96% (95% CI: 91-98%), respectively. The area under the curve (AUC) was 0.97. There was a large heterogeneity between the included studies. Studies with lesions ≤ 10 mm still had a high pooled sensitivity of 81% (95% CI: 73-90%) and specificity of 97% (95% CI: 95-100%). Studies which analyzed resected specimens had a sensitivity of 91% (95 CI: 82-99%) and specificity of 88% (95% CI: 83-94%), and studies which analyzed biopsied specimens had a sensitivity of 85% (95 CI: 74-96%) and specificity of 99% (95% CI: 98-99%).
CONCLUSIONS: ME-NBI is highly accurate and consistent to distinguish between gastric cancerous and noncancerous lesions.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app