BACKGROUND: Procedural technique may affect clinical outcomes after bioresorbable vascular scaffold (BVS) implantation. Prior studies suggesting such a relationship have not adjusted for baseline patient and lesion characteristics that may have influenced operator choice of technique and outcomes.

OBJECTIVES: This study sought to determine whether target lesion failure (TLF) (cardiac death, target-vessel myocardial infarction, or ischemia-driven target lesion revascularization) and scaffold thrombosis (ScT) rates within 3 years of BVS implantation are affected by operator technique (vessel size selection and pre- and post-dilation parameters).

METHODS: TLF and ScT rates were determined in 2,973 patients with 3,149 BVS-treated coronary artery lesions from 5 prospective studies (ABSORB II, ABSORB China, ABSORB Japan, ABSORB III, and ABSORB Extend). Outcomes through 3 years (and between 0 to 1 and 1 to 3 years) were assessed according to pre-specified definitions of optimal technique (pre-dilation, vessel sizing, and post-dilation). Multivariable analysis was used to adjust for differences in up to 18 patient and lesion characteristics.

RESULTS: Optimal pre-dilation (balloon to core laboratory-derived reference vessel diameter ratio ≥1:1), vessel size selection (reference vessel diameter ≥2.25 mm and ≤3.75 mm), and post-dilation (with a noncompliant balloon at ≥18 atm and larger than the nominal scaffold diameter, but not by >0.5 mm larger) in all BVS-treated lesions were performed in 59.2%, 81.6%, and 12.4% of patients, respectively. BVS implantation in properly sized vessels was an independent predictor of freedom from TLF through 1 year (hazard ratio [HR]: 0.67; p = 0.01) and through 3 years (HR: 0.72; p = 0.01), and of freedom from ScT through 1 year (HR: 0.36; p = 0.004). Aggressive pre-dilation was an independent predictor of freedom from ScT between 1 and 3 years (HR: 0.44; p = 0.03), and optimal post-dilation was an independent predictor of freedom from TLF between 1 and 3 years (HR: 0.55; p = 0.05).

CONCLUSIONS: In the present large-scale analysis from the major ABSORB studies, after multivariable adjustment for baseline patient and lesion characteristics, vessel sizing and operator technique were strongly associated with BVS-related outcomes during 3-year follow-up. (ABSORB II Randomized Controlled Trial [ABSORB II]; NCT01425281; ABSORB III Randomized Controlled Trial [RCT] [ABSORB-III]; NCT01751906; A Clinical Evaluation of Absorb Bioresorbable Vascular Scaffold [Absorb BVS] System in Chinese Population-ABSORB CHINA Randomized Controlled Trial [RCT] [ABSORB CHINA]; NCT01923740; ABSORB EXTEND Clinical Investigation [ABSORB EXTEND]; NCT01023789; AVJ-301 Clinical Trial: A Clinical Evaluation of AVJ-301 [Absorb BVS] in Japanese Population [ABSORB JAPAN]; NCT01844284).

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app