We have located links that may give you full text access.
Evaluation of crestal bone resorption around cylindrical and conical implants following 6 months of loading: A randomized clinical trial.
European Journal of Dentistry 2017 July
OBJECTIVE: The purpose of this clinical study was to evaluate the effect of implant body form (cylindrical and conical implants) on crestal bone levels during 6 months' follow-up after loading.
MATERIALS AND METHODS: A total of 32 SPI implants (19 conical implants/13 cylindrical implants) were randomly placed in 12 male patients using a submerged approach. None of the patients had compromising medical conditions or parafunctional habits. Periapical radiographs using the parallel technique were taken after clinical loading and 6 months later. Clinical indices including pocket depth and bleeding on probing (BOP) were recorded on 6-month follow-up. Data were analyzed by independent samples t-test and Chi-square test with a significance level of 0.05.
RESULTS: Six months after loading, crestal bone loss was 0.84 (±0.29) mm around the cylindrical implants and 0.73 (±0.62) mm around the conical types, which was not significantly different (P = 0.54). Pocket depth around the cylindrical and conical implants was 2.61 (±0.45) mm and 2.36 (±0.44) mm, respectively (P = 0.13). BOP was observed among 53.8% and 47.4% of the cylindrical implants and conical (P = 0.13). Bone loss and pocket depth in the maxilla and mandible had no significant difference (P = 0.46 and P = 0.09, respectively).
CONCLUSION: In this study, although bone loss and clinical parameters were slightly higher in the cylindrical implants, there was no significant difference between the conical- and cylindrical-shaped implants.
MATERIALS AND METHODS: A total of 32 SPI implants (19 conical implants/13 cylindrical implants) were randomly placed in 12 male patients using a submerged approach. None of the patients had compromising medical conditions or parafunctional habits. Periapical radiographs using the parallel technique were taken after clinical loading and 6 months later. Clinical indices including pocket depth and bleeding on probing (BOP) were recorded on 6-month follow-up. Data were analyzed by independent samples t-test and Chi-square test with a significance level of 0.05.
RESULTS: Six months after loading, crestal bone loss was 0.84 (±0.29) mm around the cylindrical implants and 0.73 (±0.62) mm around the conical types, which was not significantly different (P = 0.54). Pocket depth around the cylindrical and conical implants was 2.61 (±0.45) mm and 2.36 (±0.44) mm, respectively (P = 0.13). BOP was observed among 53.8% and 47.4% of the cylindrical implants and conical (P = 0.13). Bone loss and pocket depth in the maxilla and mandible had no significant difference (P = 0.46 and P = 0.09, respectively).
CONCLUSION: In this study, although bone loss and clinical parameters were slightly higher in the cylindrical implants, there was no significant difference between the conical- and cylindrical-shaped implants.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app