We have located links that may give you full text access.
Journal Article
Research Support, N.I.H., Extramural
Research Support, Non-U.S. Gov't
The association of e-cigarette use with exposure to nickel and chromium: A preliminary study of non-invasive biomarkers.
Environmental Research 2017 November
BACKGROUND: Nickel (Ni) and chromium (Cr) are components of e-cigarette heating coils. Whether e-cigarettes increase metal internal dose, however, is unknown. We assessed the association of e-cigarette use patterns and of e-liquid and aerosol metal concentrations with Ni and Cr biomarker levels in e-cigarette users from Maryland.
METHODS: We recruited 64 e-cigarette users from December 2015 to March 2016. We collected urine, saliva, and exhaled breath condensate (EBC), data on e-cigarette use, and samples from their e-cigarette device (dispenser e-liquid, aerosol, and tank e-liquid).
RESULTS: Median Ni and Cr levels were 0.73 and 0.39μg/g creatinine in urine, 2.25 and 1.53μg/L in saliva, and 1.25 and 0.29μg/L in EBC. In adjusted models, tertiles 2 and 3 of aerosol Ni concentrations were associated with 16% and 72% higher urine Ni and 202% and 321% higher saliva Ni compared to the lowest tertile. Tertile 3 of aerosol Cr levels were associated with 193% higher saliva Cr. An earlier time to first vape in the morning and more frequent coil change were associated with higher urine Ni. Tertile 2 of e-liquid consumption per week and voltage were associated with higher saliva Ni levels than tertile 1.
CONCLUSION: Positive associations of Ni and Cr aerosol concentrations with corresponding Ni and Cr biomarker levels indicate e-cigarette emissions increase metal internal dose. Increased e-cigarette use and consumption were also associated with higher Ni biomarker levels. Metal level standards are needed to prevent involuntary metal exposure among e-cigarette users.
METHODS: We recruited 64 e-cigarette users from December 2015 to March 2016. We collected urine, saliva, and exhaled breath condensate (EBC), data on e-cigarette use, and samples from their e-cigarette device (dispenser e-liquid, aerosol, and tank e-liquid).
RESULTS: Median Ni and Cr levels were 0.73 and 0.39μg/g creatinine in urine, 2.25 and 1.53μg/L in saliva, and 1.25 and 0.29μg/L in EBC. In adjusted models, tertiles 2 and 3 of aerosol Ni concentrations were associated with 16% and 72% higher urine Ni and 202% and 321% higher saliva Ni compared to the lowest tertile. Tertile 3 of aerosol Cr levels were associated with 193% higher saliva Cr. An earlier time to first vape in the morning and more frequent coil change were associated with higher urine Ni. Tertile 2 of e-liquid consumption per week and voltage were associated with higher saliva Ni levels than tertile 1.
CONCLUSION: Positive associations of Ni and Cr aerosol concentrations with corresponding Ni and Cr biomarker levels indicate e-cigarette emissions increase metal internal dose. Increased e-cigarette use and consumption were also associated with higher Ni biomarker levels. Metal level standards are needed to prevent involuntary metal exposure among e-cigarette users.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app