Add like
Add dislike
Add to saved papers

Error performances of a model-based biplane fluoroscopic system for tracking knee prosthesis during treadmill gait task.

Roentgen stereophotogrammetry analysis technique allows an accurate measurement of knee joint prosthesis position and orientation using two X-ray images. Although this technique is used generally during static procedure, it is possible to use it with a biplane fluoroscopic system to measure the prosthesis kinematics during functional tasks (e.g., gait, squat, jump) performed in a laboratory environment. However, the performance of the system in terms of errors for the measurements and the model-based matching algorithm are not well known for dynamic tasks such as walking. The goal of this study was to estimate the static and dynamic errors of a model-based biplane fluoroscopic system for a treadmill gait task and analyze the error performance according to the speed and location of the knee joint prosthesis relative to X-ray sources. The results show a static maximum error (RMSE) of 0.13° for orientation and 0.06 mm for position for prosthesis components. The dynamic errors were different for each axis of the acquisition system and each prosthesis component. The largest dynamic error was along the vertical axis for the position (RMSE = 2.42 mm) and along the medio-lateral axis (perpendicular to movement) for the orientation (RMSE = 0.95°). As expected, the error depends on the distance between the prosthesis and the source in the acquisition system as well as the linear and angular velocity of the movement. The most accurate dynamic measure was around the centroid of the acquisition system, while kinematics measurements close to the X-rays detectors gave the worst errors.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app