OBJECTIVE: The mechanical imaging of lumps in tissues via surface measurements can permit the noninvasive detection of disease-related differences in body tissues. We present and evaluate sensing techniques for the mechanical imaging of soft tissues, using a highly compliant electronic sensing array.
METHODS: We developed a mechanical imaging system for capturing tissue properties during automatic- or human-guided palpation. It combines extremely compliant capacitive tactile sensors based on soft polymers and microfluidic electrodes with custom electronic data acquisition hardware, and new algorithms for enhanced tactile imaging by reference to nominal tissue responses.
RESULTS: We demonstrate that the system is able to image simulated tumors (lumps), yielding accurate estimates of cross-sectional area independent of embedding depth. In addition, as a proof of concept, we show that similar tactile images can be obtained when the sensor is worn on a palpating finger.
CONCLUSION: Soft capacitive sensors can accurately image lumps in soft tissue provided that care is taken to control and compensate for electrical and mechanical background signals.
SIGNIFICANCE: The results underline the utility of soft electronic sensors for applications in medical imaging or clinical practices of palpation.
METHODS: We developed a mechanical imaging system for capturing tissue properties during automatic- or human-guided palpation. It combines extremely compliant capacitive tactile sensors based on soft polymers and microfluidic electrodes with custom electronic data acquisition hardware, and new algorithms for enhanced tactile imaging by reference to nominal tissue responses.
RESULTS: We demonstrate that the system is able to image simulated tumors (lumps), yielding accurate estimates of cross-sectional area independent of embedding depth. In addition, as a proof of concept, we show that similar tactile images can be obtained when the sensor is worn on a palpating finger.
CONCLUSION: Soft capacitive sensors can accurately image lumps in soft tissue provided that care is taken to control and compensate for electrical and mechanical background signals.
SIGNIFICANCE: The results underline the utility of soft electronic sensors for applications in medical imaging or clinical practices of palpation.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app