Value of Digital Breast Tomosynthesis versus Additional Views for the Assessment of Screen-Detected Abnormalities - a First Analysis.
Breast Care 2017 May
BACKGROUND: The purpose of this study was to countercheck the equivalence of single-view digital breast tomosynthesis (DBT) or DBT with additional views (DBT+AV) compared to traditional standard assessment by additional views (AV) in patients with a screen-detected abnormality.
PATIENTS AND METHODS: Patients with a screen-detected abnormality were consecutively invited to obtain 1 single-view wide-angle DBT in addition to the indicated AV. The study was approved by the local ethics committee and by the Federal Office for Radiation Protection.
RESULTS: This study is based on 311 lesions in 285 patients with a follow-up of > 2 years and/or biopsy. Counting BI-RADS 0 and 3 as positive calls, the sensitivity/specificity of DBT+AV versus DBT only versus AV only were 96.4/54.3%, 96.4/56.6%, and 90.9/42.2%, respectively. The specificities and BI-RADS classifications differed significantly (p < 0.01). AV appeared unnecessary in 88.8% of the cases.
CONCLUSION: DBT appeared to be at least equivalent to AV for assessing indeterminate screen-detected lesions and could replace AV for most lesions. To obtain the extra information appears possible without increasing the overall radiation dose. Subsequent blinded reader studies are ongoing.
PATIENTS AND METHODS: Patients with a screen-detected abnormality were consecutively invited to obtain 1 single-view wide-angle DBT in addition to the indicated AV. The study was approved by the local ethics committee and by the Federal Office for Radiation Protection.
RESULTS: This study is based on 311 lesions in 285 patients with a follow-up of > 2 years and/or biopsy. Counting BI-RADS 0 and 3 as positive calls, the sensitivity/specificity of DBT+AV versus DBT only versus AV only were 96.4/54.3%, 96.4/56.6%, and 90.9/42.2%, respectively. The specificities and BI-RADS classifications differed significantly (p < 0.01). AV appeared unnecessary in 88.8% of the cases.
CONCLUSION: DBT appeared to be at least equivalent to AV for assessing indeterminate screen-detected lesions and could replace AV for most lesions. To obtain the extra information appears possible without increasing the overall radiation dose. Subsequent blinded reader studies are ongoing.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app