PURPOSE: Endoscopic examinations are frequently-used procedures for patients with head and neck cancer undergoing radiotherapy, but radiation treatment plans are created on computed tomography (CT) scans. Image registration between endoscopic video and CT could be used to improve treatment planning and analysis of radiation-related normal tissue toxicity. The purpose of this study was to explore the feasibility of endoscopy-CT image registration without prospective physical tracking of the endoscope during the examination.
METHODS: A novel registration technique called Location Search was developed. This technique uses physical constraints on the endoscope's view direction to search for the virtual endoscope coordinates that maximize the similarity between the endoscopic video frame and the virtual endoscopic image. Its performance was tested on phantom and patient images and compared to an established registration technique, Frame-To-Frame Tracking.
RESULTS: In phantoms, Location Search had average registration errors of 0.55 ± 0.60 cm for point measurements and 0.29 ± 0.15 cm for object surface measurements. Frame-To-Frame Tracking achieved similar results on some frames, but it failed on others due to the virtual endoscope becoming lost. This weakness was more pronounced in patients, where Frame-To-Frame tracking could not make it through the nasal cavity. On successful patient video frames, Location Search was able to find endoscope positions with an average distance of 0.98 ± 0.53 cm away from the ground truth positions. However, it failed on many frames due to false similarity matches caused by anatomical structural differences between the endoscopic video and the virtual endoscopic images.
CONCLUSIONS: Endoscopy-CT image registration without prospective physical tracking of the endoscope is possible, but more development is required to achieve an accuracy suitable for clinical translation.
METHODS: A novel registration technique called Location Search was developed. This technique uses physical constraints on the endoscope's view direction to search for the virtual endoscope coordinates that maximize the similarity between the endoscopic video frame and the virtual endoscopic image. Its performance was tested on phantom and patient images and compared to an established registration technique, Frame-To-Frame Tracking.
RESULTS: In phantoms, Location Search had average registration errors of 0.55 ± 0.60 cm for point measurements and 0.29 ± 0.15 cm for object surface measurements. Frame-To-Frame Tracking achieved similar results on some frames, but it failed on others due to the virtual endoscope becoming lost. This weakness was more pronounced in patients, where Frame-To-Frame tracking could not make it through the nasal cavity. On successful patient video frames, Location Search was able to find endoscope positions with an average distance of 0.98 ± 0.53 cm away from the ground truth positions. However, it failed on many frames due to false similarity matches caused by anatomical structural differences between the endoscopic video and the virtual endoscopic images.
CONCLUSIONS: Endoscopy-CT image registration without prospective physical tracking of the endoscope is possible, but more development is required to achieve an accuracy suitable for clinical translation.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app