We have located links that may give you full text access.
Sensitivity, Specificity and Predictive Value of Heart Rate Variability Indices in Type 1 Diabetes Mellitus.
Arquivos Brasileiros de Cardiologia 2017 March
BACKGROUND: Heart rate variability (HRV) indices may detect autonomic changes with good diagnostic accuracy. Type diabetes mellitus (DM) individuals may have changes in autonomic modulation; however, studies of this nature in this population are still scarce.
OBJECTIVE: To compare HRV indices between and assess their prognostic value by measurements of sensitivity, specificity and predictive values in young individuals with type 1 DM and healthy volunteers.
METHODS: In this cross-sectional study, physical and clinical assessment was performed in 39 young patients with type 1 DM and 43 young healthy controls. For HRV analysis, beat-to-beat heart rate variability was measured in dorsal decubitus, using a Polar S810i heart rate monitor, for 30 minutes. The following indices were calculated: SDNN, RMSSD, PNN50, TINN, RRTri, LF ms2, HF ms2, LF un, HF un, LF/HF, SD1, SD2, SD1/SD2, and ApEn.
RESULTS: Type 1 DM subjects showed a decrease in sympathetic and parasympathetic activities, and overall variability of autonomic nervous system. The RMSSD, SDNN, PNN50, LF ms2, HF ms2, RRTri, SD1 and SD2 indices showed greater diagnostic accuracy in discriminating diabetic from healthy individuals.
CONCLUSION: Type 1 DM individuals have changes in autonomic modulation. The SDNN, RMSSD, PNN50, RRtri, LF ms2, HF ms2, SD1 and SD2 indices may be alternative tools to discriminate individuals with type 1 DM.
OBJECTIVE: To compare HRV indices between and assess their prognostic value by measurements of sensitivity, specificity and predictive values in young individuals with type 1 DM and healthy volunteers.
METHODS: In this cross-sectional study, physical and clinical assessment was performed in 39 young patients with type 1 DM and 43 young healthy controls. For HRV analysis, beat-to-beat heart rate variability was measured in dorsal decubitus, using a Polar S810i heart rate monitor, for 30 minutes. The following indices were calculated: SDNN, RMSSD, PNN50, TINN, RRTri, LF ms2, HF ms2, LF un, HF un, LF/HF, SD1, SD2, SD1/SD2, and ApEn.
RESULTS: Type 1 DM subjects showed a decrease in sympathetic and parasympathetic activities, and overall variability of autonomic nervous system. The RMSSD, SDNN, PNN50, LF ms2, HF ms2, RRTri, SD1 and SD2 indices showed greater diagnostic accuracy in discriminating diabetic from healthy individuals.
CONCLUSION: Type 1 DM individuals have changes in autonomic modulation. The SDNN, RMSSD, PNN50, RRtri, LF ms2, HF ms2, SD1 and SD2 indices may be alternative tools to discriminate individuals with type 1 DM.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app