We have located links that may give you full text access.
Maintenance of Low-Pressure Carburising Furnaces: A Source of PAH Exposure.
Annals of Work Exposures and Health 2017 April 2
Objectives: Low-pressure carburising is a new technology used to harden steel; the process has been shown to be a source of considerable polycyclic aromatic hydrocarbons (PAH) pollution. Some PAH are carcinogenic, and activities such as furnace maintenance may thus represent a risk to workers. Occupational exposure during these operations should therefore be assessed.
Methods: In this study, the PAH-related carcinogenic risk associated with furnace maintenance was assessed by monitoring atmospheric levels of benzo[a]pyrene (BaP), a representative marker, alongside urinary levels of 3-hydroxybenzo[a]pyrene (3-OHBaP), one of its metabolites. PAH exposure levels were monitored during seven sampling campaigns in four different factories specialized in heat-treatment of mechanical workpieces for the automotive and helicopter industries. Two types of furnace were studied, and 37 individuals were monitored.
Results: Values up to 20-fold the French regulatory value of 150 ng/m3 for atmospheric BaP, and, for urinary 3-OHBaP values up to 40-fold the French biological limit value (BLV) of 0.35 nmol/mol of creatinine were detected. Very high concentrations of BaP, close to or even exceeding those found in coal-tar pitch (up to about 20 g/kg), were measured in residues (tars, dusts) deposited inside the furnace. Even when adequate and suitable personal protective equipment was used, urinary 3-OHBaP values often exceeded the BLV. We hypothesize that this exposure is linked to insidious and fortuitous dermal contamination through contact with factory equipment and staining.
Methods: In this study, the PAH-related carcinogenic risk associated with furnace maintenance was assessed by monitoring atmospheric levels of benzo[a]pyrene (BaP), a representative marker, alongside urinary levels of 3-hydroxybenzo[a]pyrene (3-OHBaP), one of its metabolites. PAH exposure levels were monitored during seven sampling campaigns in four different factories specialized in heat-treatment of mechanical workpieces for the automotive and helicopter industries. Two types of furnace were studied, and 37 individuals were monitored.
Results: Values up to 20-fold the French regulatory value of 150 ng/m3 for atmospheric BaP, and, for urinary 3-OHBaP values up to 40-fold the French biological limit value (BLV) of 0.35 nmol/mol of creatinine were detected. Very high concentrations of BaP, close to or even exceeding those found in coal-tar pitch (up to about 20 g/kg), were measured in residues (tars, dusts) deposited inside the furnace. Even when adequate and suitable personal protective equipment was used, urinary 3-OHBaP values often exceeded the BLV. We hypothesize that this exposure is linked to insidious and fortuitous dermal contamination through contact with factory equipment and staining.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app