Add like
Add dislike
Add to saved papers

Modeling electrical stimulation of retinal ganglion cell with optimizing additive noises for reducing threshold and energy consumption.

BACKGROUND: Epiretinal prosthesis is one device for the treatment of blindness, which target retinal ganglion cells (RGCs) by electrodes on retinal surface. The stimulating current of epiretinal prosthesis is an important factor that influences the safety threshold and visual perception. Stochastic resonance (SR) can be used to enhance the detection and transmission of subthreshold stimuli in neurons. Here, it was assumed that SR was a potential way to improve the performance of epiretinal prosthesis. The effect of noises on the response of RGCs to electrical stimulation and the energy of stimulating current was studied based on a RGC model.

METHODS: The RGC was modeled as a multi-compartment model consisting of dendrites and its branches, soma and axon. To evoke SR, a subthreshold signal, a series of bipolar rectangular pulse sequences, plus stochastic biphasic pulse sequences as noises, were used as a stimulus to the model. The SR-type behavior in the model was characterized by a "power norm" measure. To decrease energy consumption of the stimulation waveform, the stochastic biphasic pulse sequences were only added to the cathode and anode phase of the subthreshold pulse and the noise parameters were optimized by using a genetic algorithm (GA).

RESULTS: When certain intensity of noise is added to the subthreshold signal, RGC model can fire. With the noise's RMS amplitudes increased, more spikes were elicited and the curve of power norm presents the inverted U-like graph. The larger pulse width of stochastic biphasic pulse sequences resulted in higher power norm. The energy consumption and charges of the single bipolar rectangular pulse without noise in threshold level are 468.18 pJ, 15.30 nC, and after adding optimized parameters's noise to the subthreshold signal, they became 314.8174 pJ, 11.9281 nC and were reduced by 32.8 and 22.0%, respectively.

CONCLUSIONS: The SR exists in the RGC model and can enhance the representation of RGC model to the subthreshold signal. Adding the stochastic biphasic pulse sequences to the cathode and anode phase of the subthreshold signal helps to reduce stimulation threshold, energy consumption and charge of RGC stimulation. These may be helpful for improving the performance of epiretinal prosthesis.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app