Long-Term Prognosis of Patients with an Implantable Cardioverter-Defibrillator in Korea.
Yonsei Medical Journal 2017 May
PURPOSE: The objective of this study was to elucidate the long-term prognosis of patients with implantable cardioverter-defibrillators (ICDs) in Korea.
MATERIALS AND METHODS: We enrolled 405 patients (age, 57.7±16.7 years; 311 men) who had undergone ICD implantation. The patients were divided into three groups: heart failure (HF) and ICD for primary (group 1, n=118) and secondary prevention (group 2, n=93) and non-HF (group 3, n=194). We compared appropriate and inappropriate ICD therapy delivery among the groups and between high- (heart rate ≥200 /min) and low-rate (<200 /min) ICD therapy zones.
RESULTS: During the follow-up period (58.9±49.8 months), the annual appropriate ICD therapy rate was higher in group 2 (10.4%) than in groups 1 and 3 (6.1% and 5.9%, respectively, p<0.001). There were no significant differences in annual inappropriate ICD therapy rate among the three groups. In group 1, the annual appropriate ICD therapy rate was significantly lower in patients with a high-rate versus a low-rate therapy zone (4.5% and 9.6%, respectively, p=0.026). In group 3, the annual inappropriate ICD therapy rate was significantly lower in patients with a high-rate versus a low-rate therapy zone (3.1% and 4.0%, respectively, p=0.048).
CONCLUSION: Appropriate ICD therapy rates are not low in Korean patients with ICD, relative to prior large-scale studies in Western countries. Appropriate and inappropriate ICD therapy could be reduced by a high-rate therapy zone in patients with HF and ICD for primary prevention, as well as non-HF patients, respectively.
MATERIALS AND METHODS: We enrolled 405 patients (age, 57.7±16.7 years; 311 men) who had undergone ICD implantation. The patients were divided into three groups: heart failure (HF) and ICD for primary (group 1, n=118) and secondary prevention (group 2, n=93) and non-HF (group 3, n=194). We compared appropriate and inappropriate ICD therapy delivery among the groups and between high- (heart rate ≥200 /min) and low-rate (<200 /min) ICD therapy zones.
RESULTS: During the follow-up period (58.9±49.8 months), the annual appropriate ICD therapy rate was higher in group 2 (10.4%) than in groups 1 and 3 (6.1% and 5.9%, respectively, p<0.001). There were no significant differences in annual inappropriate ICD therapy rate among the three groups. In group 1, the annual appropriate ICD therapy rate was significantly lower in patients with a high-rate versus a low-rate therapy zone (4.5% and 9.6%, respectively, p=0.026). In group 3, the annual inappropriate ICD therapy rate was significantly lower in patients with a high-rate versus a low-rate therapy zone (3.1% and 4.0%, respectively, p=0.048).
CONCLUSION: Appropriate ICD therapy rates are not low in Korean patients with ICD, relative to prior large-scale studies in Western countries. Appropriate and inappropriate ICD therapy could be reduced by a high-rate therapy zone in patients with HF and ICD for primary prevention, as well as non-HF patients, respectively.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app