A Biomechanical Comparison of Allograft Tendons for Ligament Reconstruction.

BACKGROUND: Allograft tendons are frequently used for ligament reconstruction about the knee, but they entail availability and cost challenges. The identification of other tissues that demonstrate equivalent performance to preferred tendons would improve limitations. Hypothesis/Purpose: We compared the biomechanical properties of 4 soft tissue allograft tendons: tibialis anterior (TA), tibialis posterior (TP), peroneus longus (PL), and semitendinosus (ST). We hypothesized that allograft properties would be similar when standardized by the looped diameter.

STUDY DESIGN: Controlled laboratory study.

METHODS: This study consisted of 2 arms evaluating large and small looped-diameter grafts: experiment A consisted of TA, TP, and PL tendons (n = 47 each) with larger looped diameters of 9.0 to 9.5 mm, and experiment B consisted of TA, TP, PL, and ST tendons (n = 53 each) with smaller looped diameters of 7.0 to 7.5 mm. Each specimen underwent mechanical testing to measure the modulus of elasticity (E), ultimate tensile force (UTF), maximal elongation at failure, ultimate tensile stress (UTS), and ultimate tensile strain (UTε).

RESULTS: Experiment A: No significant differences were noted among tendons for UTF, maximal elongation at failure, and UTϵ. UTS was significantly higher for the PL (54 MPa) compared with the TA (44 MPa) and TP (43 MPa) tendons. E was significantly higher for the PL (501 MPa) compared with the TP (416 MPa) tendons. Equivalence testing showed that the TP and PL tendon properties were equivalent or superior to those of the TA tendons for all outcomes. Experiment B: All groups exhibited a similar E. UTF was again highest in the PL tendons (2294 N) but was significantly different from only the ST tendons (1915 N). UTϵ was significantly higher for the ST (0.22) compared with the TA (0.19) and TP (0.19) tendons. Equivalence testing showed that the TA, TP, and PL tendon properties were equivalent or superior to those of the ST tendons.

CONCLUSION: Compared with TA tendons, TP and PL tendons of a given looped diameter exhibited noninferior initial biomechanical strength and stiffness characteristics. ST tendons were mostly similar to TA tendons but exhibited a significantly higher elongation/UTϵ and smaller cross-sectional area. For smaller looped-diameter grafts, all tissues were noninferior to ST tendons. In contrast to previous findings, PL tendons proved to be equally strong.

CLINICAL RELEVANCE: The results of this study should encourage surgeons to use these soft tissue allografts interchangeably, which is important as the number of ligament reconstructions performed with allografts continues to rise.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app