We have located links that may give you full text access.
Identification and analytical characterization of six synthetic cannabinoids NNL-3, 5F-NPB-22-7N, 5F-AKB-48-7N, 5F-EDMB-PINACA, EMB-FUBINACA, and EG-018.
Drug Testing and Analysis 2017 August
Clinical and forensic toxicology laboratories are continuously confronted by analytical challenges when dealing with the new psychoactive substances phenomenon. The number of synthetic cannabinoids, the chemical diversity, and the speed of emergence make this group of compounds particularly challenging in terms of detection, monitoring, and responding. Three indazole 7N positional isomer synthetic cannabinoids, two ethyl 2-amino-3-methylbutanoate-type synthetic cannabinoids, and one 9H-carbazole substituted synthetic cannabinoid were identified in seized materials. These six synthetic cannabinoid derivatives included: 1H-benzo[d] [1,2,3]triazol-1-yl 1-(5-fluoropentyl)-1H-pyrrolo[2,3-b]pyridine-3-carboxylate (NNL-3, 1), quinolin-8-yl 1-(5-fluoropentyl)-1H-pyrrolo[2,3-b]pyridine-3-carboxylate (5F-NPB-22-7N, 2), N-((1 s,3 s)-adamantan-1-yl)-1-(5-fluoropentyl)-1H-pyrrolo[2,3-b]pyridine-3-carboxamide (5F-AKB-48-7N, 3), ethyl 2-(1-(5-fluoropentyl)-1H-indazole-3-carboxamido)-3,3-dimethylbutanoate (5F-EDMB-PINACA, 4), ethyl 2-(1-(4-fluorobenzyl)-1H-indazole-3-carboxamido)-3-methylbutanoate (EMB-FUBINACA, 5), and naphthalen-1-yl(9-pentyl-9H-carbazol-3-yl)methanone (EG-018, 6). The identification was based on ultra-high-performance liquid chromatography-quadrupole time-of-flight-mass spectrometry (UHPLC-QTOF-MS), gas chromatography-mass spectrometry (GC-MS), and nuclear magnetic resonance spectroscopy (NMR). The analytical characterization of these six synthetic cannabinoids was described, so as to assist forensic laboratories in identifying these compounds or other substances with similar structure in their case work. To our knowledge, no analytical data about the compounds 1-5 have appeared until now, making this the first report on these compounds. The GC-MS data of 6 has been reported, but this study added the LC-MS, NMR, and Fourier transform infrared (FTIR), data to render the analytical data collection process more complete. Copyright © 2017 John Wiley & Sons, Ltd.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app