Add like
Add dislike
Add to saved papers

Estimating head and neck tissue dose from x-ray scatter to physicians performing x-ray guided cardiovascular procedures: a phantom study.

Physicians performing x-ray guided interventional procedures have a keen interest in radiation safety. Radiation dose to tissues and organs of the head and neck are of particular interest because they are not routinely protected by wearable radiation safety devices. This study was conducted to facilitate estimation of radiation dose to tissues of the head and neck of interventional physicians based on the dose recorded by a personal dosimeter worn on the left collar. Scatter beam qualities maximum energy and HVL were measured for 40 scatter beams emitting from an anthropomorphic patient phantom. Variables of the scatter beams included scatter angle (35° and 90°), primary beam peak tube potential (60, 80, 100, and 120 kVp), and 5 Cu spectral filter thicknesses (0-0.9 mm). Four reference scatter beam qualities were selected to represent the range of scatter beams realized in a typical practice. A general radiographic x-ray tube was tuned to produce scatter-equivalent radiographic beams and used to simultaneously expose the head and neck of an anthropomorphic operator phantom and radiochromic film. The geometric relationship between the x-ray source of the scatter-equivalent beams and the operator phantom was set to mimic that between a patient and physician performing an invasive cardiovascular procedure. Dose to the exterior surface of the operator phantom was measured with both 3 × 3 cm(2) pieces of film and personal dosimeters positioned at the location of the left collar. All films were scanned with a calibrated flatbed scanner, which converted the film's reflective density to dose. Films from the transverse planes of the operator phantom provided 2D maps of the dose distribution within the phantom. These dose maps were normalized by the dose at the left collar, providing 2D percent of left collar dose (LCD) maps. The percent LCD maps were overlain with bony anatomy CT images of the operator phantom and estimates of percent LCD to the left, right and whole brain, brain stem, lenses of the eyes, and carotid arteries were calculated. Per expectation, results indicated greater percent dose to superficial versus deep tissues and increasing percent dose to deep tissues with increasing scatter-equivalent beam energy and HVL. The results enable estimation of the scatter dose to tissues of the head and neck of interventional physicians based on occupational dose measured by a personal dosimeter worn at the collar outside the protective apron.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app