BACKGROUND: To retrospectively compare the operation time, success rate and efficacy between unidirectional and bidirectional procedures in the treatment of central venous occlusion diseases (CVOD), assess the advantages of the bidirectional approach, and determine the characteristics of CVOD appropriate for the bidirectional approach treatment.

METHODS: A total of 49 patients who underwent endovascular interventions with all relevant data between January 2011 and December 2015 at the First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China, were included in this retrospective study, and were categorized into two groups: the 19 patients in group 1 had undergone percutaneous transluminal venoplasty (PTV) via a conventional technique (unidirectional procedure from the vein distal or proximal to the obstructive lesion), and the 30 in group 2 had undergone flossing wire technique (bidirectional procedure from femoral vein and the vein distal to obstructive lesion and using a flossing wire technique). The technical success rate, the fluoroscopy time in the procedure, perioperative complications, and patency were evaluated retrospectively.

RESULTS: Compared with group 1, group 2 had a higher initial technical success rate (83.33% vs. 47.36%, p = 0.012) but a shorter fluoroscopy time (82.6 ± 26.1 vs. 116.1 ± 42.1, p = 0.048). Receiver operating characteristic (ROC) analysis indicated that a lesion with a length of 6.5 cm was the best predictor of technique success (p = 0.02) in group 1, but no cut-off value was identified for group 2. There were no significant differences in perioperative complications between these two groups. The complication rates were 31.58% (6/19) in group 1 and 6.67% (2/30) in group 2, (p = 0.043), respectively. No significant difference was observed between these two groups with respect to the stent patency rate.

CONCLUSION: Compared with the conventional technique, the flossing wire technique has a higher success rate, shorter fluoroscopy time, fewer complications and similar patency rate. It is a feasible treatment for CVOD, especially for long obstructive lesions.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app