We have located links that may give you full text access.
Schneiderian Membrane Perforation Rate and Increase in Bone Temperature During Maxillary Sinus Floor Elevation by Means of Er: YAG Laser-An Animal Study in Pigs.
Implant Dentistry 2017 April
PURPOSE: To assess the time of preparation, bone temperature increase, and the Schneiderian membrane perforation rate during maxillary sinus floor elevation.
MATERIALS AND METHODS: The research included 30 maxillary sinuses (n = 30) of a pig, divided into 2 groups (n = 15). The lateral bony windows were created using Er:YAG laser (200 mJ, 15 Hz, energy density: 25.48 J/cm) and a diamond bur (control). The membrane was elevated using laser (50 mJ, 50 Hz) and hand instruments. The bone temperature was measured by K-type thermocouple.
RESULTS: Significantly lower rates of the Schneiderian membrane perforation were found in the laser group (6.67%) compared with the bur (33%) (P < 0.05). The significant higher increase in temperature (mean 7.6°C) was found in the experimental group as compared with the control group (mean 2°C) (P = 0.0000033). The average time necessary for the laser bony window osteotomy was 10 minutes and 37 seconds, whereas using the bur required middling 5 minutes and 50 seconds (P = 0.000283).
CONCLUSION: The application of Er:YAG laser may significantly reduce the risk of iatrogenic perforation of the Schneiderian membrane and does not cause an irreversible thermal damage in a pig model.
MATERIALS AND METHODS: The research included 30 maxillary sinuses (n = 30) of a pig, divided into 2 groups (n = 15). The lateral bony windows were created using Er:YAG laser (200 mJ, 15 Hz, energy density: 25.48 J/cm) and a diamond bur (control). The membrane was elevated using laser (50 mJ, 50 Hz) and hand instruments. The bone temperature was measured by K-type thermocouple.
RESULTS: Significantly lower rates of the Schneiderian membrane perforation were found in the laser group (6.67%) compared with the bur (33%) (P < 0.05). The significant higher increase in temperature (mean 7.6°C) was found in the experimental group as compared with the control group (mean 2°C) (P = 0.0000033). The average time necessary for the laser bony window osteotomy was 10 minutes and 37 seconds, whereas using the bur required middling 5 minutes and 50 seconds (P = 0.000283).
CONCLUSION: The application of Er:YAG laser may significantly reduce the risk of iatrogenic perforation of the Schneiderian membrane and does not cause an irreversible thermal damage in a pig model.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app