Add like
Add dislike
Add to saved papers

Stability of ionized calcium measurements at concentrations less than 0.3 mmol/L by point-of-care blood gas instruments: application for postfilter calcium quality control in patients with citrate anticoagulation during extracorporeal circulation.

Background Measurements of ionized calcium (Ca(2+)) at concentrations less than 0.3 mmol/L are required for postfilter control in patients who receive extracorporeal circulation with sodium citrate anticoagulation. This study evaluates the stability of the Ca(2+) measurements at such concentrations. Methods The stability of the Ca(2+) measurements was tested by measuring daily the external standard Qualicheck concentration 3 s7950, Radiometer (0.22-0.25 mmol/L) by blood gas instruments ABL800 and ABL90, Radiometer. Two different Ca(2+) membrane lots were tested for the usual membrane lifetime of 12 weeks at ABL800 instruments. For the ABL90 instrument, the sensor cassette (with Ca(2+) membrane and electrode) was replaced after four weeks as required. Results We observed over 40% Ca(2+) increase within the usual 12 weeks lifetime of the Ca(2+) membrane at the ABL800 instruments. Measurements of Ca(2+) at concentrations less than 0.3 mmol/L were within acceptable limits for both ABL800 and ABL90 instruments when Ca(2+) membrane and sensor cassette were replaced after four weeks. Conclusions For ABL800 instruments, it is necessary to use an extra quality control (<0.3 mmol/L) in addition to the usual quality controls to monitor Ca(2+) measurements below 0.3 mmol/L. The acceptable stability of the Ca(2+) measurements can be achieved by the Ca(2+) membrane and sensor cassette replacement after four weeks. If the usual 12 weeks of Ca(2+) membrane lifetime is maintained, it may result in a clinically significant overestimation of Ca(2+) by ABL800 instruments.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app