MRI with phaseless encoding.
Magnetic Resonance in Medicine 2017 September
PURPOSE: Fourier encoded MRI signal is complex and, therefore, sensitive to uncontrolled phase variations caused, e.g., by object motion. An alternative encoding is proposed which leads to phaseless (positive real) signals and allows the phase fluctuations to be removed by simple magnitude calculation before the Fourier transform.
THEORY AND METHODS: Phaseless encoding uses harmonic modulation of the longitudinal magnetization with different frequencies and phases before excitation. It can be combined with Fourier encoding of complementary dimensions to produce, e.g., a 3D version of echo planar imaging insensitive to intershot phase variations. It can also be mixed with Fourier encoding of the same dimension allowing a high-resolution image to be obtained from magnitude-reconstructed low-resolution components. The latter is a generalization of the super-resolution MRI with microscopic tagging proposed recently. Improved reconstruction for this technique was adopted from its optical analogue, harmonic excitation light microscopy (HELM).
RESULTS: Artifact free images were obtained despite phase fluctuations caused by random receiver reference and object motion during diffusion weighting. Proposed reconstruction of mixed-encoded data reaches higher resolution than the original super-resolution method.
CONCLUSION: Spatial information can be encoded in the magnitude of the MR signal rendering the experiment insensitive to phase fluctuations. Magn Reson Med 78:1029-1037, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
THEORY AND METHODS: Phaseless encoding uses harmonic modulation of the longitudinal magnetization with different frequencies and phases before excitation. It can be combined with Fourier encoding of complementary dimensions to produce, e.g., a 3D version of echo planar imaging insensitive to intershot phase variations. It can also be mixed with Fourier encoding of the same dimension allowing a high-resolution image to be obtained from magnitude-reconstructed low-resolution components. The latter is a generalization of the super-resolution MRI with microscopic tagging proposed recently. Improved reconstruction for this technique was adopted from its optical analogue, harmonic excitation light microscopy (HELM).
RESULTS: Artifact free images were obtained despite phase fluctuations caused by random receiver reference and object motion during diffusion weighting. Proposed reconstruction of mixed-encoded data reaches higher resolution than the original super-resolution method.
CONCLUSION: Spatial information can be encoded in the magnitude of the MR signal rendering the experiment insensitive to phase fluctuations. Magn Reson Med 78:1029-1037, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app