Controlled Clinical Trial
Journal Article
Add like
Add dislike
Add to saved papers

High-flow humidified nasal oxygenation vs. standard face mask oxygenation.

Anaesthesia 2016 November
Ten healthy volunteers received oxygen for 1 min, 2 min and 3 min at 10 l.min-1 via a face mask, or humidified oxygen at 60 l.min-1 via nasal prongs (OptiflowTM ) with the mouth closed and with the mouth open. The mean (SD) end-tidal oxygen partial pressure after 3 min face mask and Optiflow oxygenation, with mouth closed and open, were: 88.5 (6.2) kPa; 85.6 (6.4) kPa and 48.7 (26.4) kPa, respectively, p = 0.001. The equivalent mean (SD) transcutaneous oxygen partial pressures were: 34.6 (5.4) kPa; 36.4 (6.5) kPa and 25.5 (15.7) kPa, respectively, p = 0.03. High-flow humidified nasal oxygenation for 3 min with the mouth closed was as effective as 3 min face mask oxygenation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app