Add like
Add dislike
Add to saved papers

'Pseudofailure' of spinal cord stimulation for neuropathic pain following a new severe noxious stimulus: learning points from a case series of failed spinal cord stimulation for complex regional pain syndrome and failed back surgery syndrome.

Failure of spinal cord stimulation (SCS) may be due to hardware problems, migration of electrodes and, in the long-term, plasticity in the spinal cord with habituation to the stimulation current. We describe a series of seven patients who experienced acute therapeutic loss of SCS effects following an acute nociceptive event unrelated to primary pathology. There were no hardware problems. We called this 'Pseudofailure', as the effective stimulation returned in all patients following a period off stimulation or reprogramming. This phenomenon has not been reported previously in the literature. Over a 4-year period, we managed seven patients with this feature: four had received SCS for complex regional pain syndrome and three for failed back surgery syndrome. In all seven cases, there was cessation of the pain relief afforded by SCS following an acute painful event: four patients had trauma, two patients had domestic electric shock and one patient suffered shingles (varicella zoster infection). We excluded hardware-related problems in all cases. In two patients, SCS effects could be regained by an initial attempt at reprogramming. In the remaining five cases reprogramming was unsuccessful, and stimulation was switched off for several months before recommencing, when we discovered a return of good therapeutic effect. We conclude that SCS may seem to fail following a separate strong nociceptive stimulus. Stimulation may be regained with reprogramming or following a period with stimulation switched off. We would, therefore, advise against removal of SCS hardware in the first instance.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app