Predicting arterial blood gas and lactate from central venous blood analysis in critically ill patients: a multicentre, prospective, diagnostic accuracy study.

BACKGROUND: The estimation of arterial blood gas and lactate from central venous blood analysis and pulse oximetry [Formula: see text] readings has not yet been extensively validated.

METHODS: In this multicentre, prospective study performed in 590 patients with acute circulatory failure, we measured blood gases and lactate in simultaneous central venous and arterial blood samples at 6 h intervals during the first 24 h after insertion of central venous and arterial catheters. The study population was randomly divided in a 2:1 ratio into model derivation and validation sets. We derived predictive models of arterial pH, carbon dioxide partial pressure, oxygen saturation, and lactate, using clinical characteristics, [Formula: see text], and central venous blood gas values as predictors, and then tested their performance in the validation set.

RESULTS: In the validation set, the agreement intervals between predicted and actual values were -0.078/+0.084 units for arterial pH, -1.32/+1.36 kPa for arterial carbon dioxide partial pressure, -5.15/+4.47% for arterial oxygen saturation, and -1.07/+1.05 mmol litre(-1) for arterial lactate (i.e. around two times our predefined clinically tolerable intervals for all variables). This led to ∼5% (or less) of extreme-to-extreme misclassifications, thus giving our predictive models only marginal agreement. Thresholds of predicted variables (as determined from the derivation set) showed high predictive values (consistently >94%), to exclude abnormal arterial values in the validation set.

CONCLUSIONS: Using clinical characteristics, [Formula: see text], and central venous blood analysis, we predicted arterial blood gas and lactate values with marginal accuracy in patients with circulatory failure. Further studies are required to establish whether the developed models can be used with acceptable safety.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app