Intra-abdominal packing with laparotomy pads and QuikClot™ during damage control laparotomy: A safety analysis.

Injury 2017 January
BACKGROUND: Intra-abdominal packing with laparotomy pads (LP) is a common and rapid method for hemorrhage control in critically injured patients. Combat Gauze™ and Trauma Pads™ ([QC] Z-Medica QuikClot® ) are kaolin impregnated hemostatic agents, that in addition to LP, may improve hemorrhage control. While QC packing has been effective in a swine liver injury model, QC remains unstudied for human intra-abdominal use. We hypothesized QC packing during damage control laparotomy (DCL) better controls hemorrhage than standard packing and is safe for intracorporeal use.

METHODS: A retrospective review (2011-2014) at a Level-I Trauma Center reviewed all patients who underwent DCL with intentionally retained packing. Clinical characteristics, intraoperative and postoperative parameters, and outcomes were compared with respect to packing (LP vs. LP+QC). All complications occurring within the patients' hospital stays were reviewed. A p≤0.05 was considered significant.

RESULTS: 68 patients underwent DCL with packing; (LP n=40; LP+QC n=28). No difference in age, BMI, injury mechanism, ISS, or GCS was detected (Table 1, all p>0.05). LP+QC patients had a lower systolic blood pressure upon ED presentation and greater blood loss during index laparotomy than LP patients. LP+QC patients received more packed red blood cell and fresh frozen plasma resuscitation during index laparotomy (both p<0.05). Despite greater physiologic derangement in the LP+QC group, there was no difference in total blood products required after index laparotomy until abdominal closure (LP vs LP+QC; p>0.05). After a median of 2days until abdominal closure in both groups, no difference in complications rates attributable to intra-abdominal packing (LP vs LP+QC) was detected.

CONCLUSION: While the addition of QC to LP packing did not confer additional benefit to standard packing, there was no additional morbidity identified with its use. The surgeons at our institution now select augmented packing with QC for sicker patients, as we believe this may have additional advantage over standard LP packing. A randomized controlled trial is warranted to further evaluate the intra-abdominal use of advanced hemostatic agents, like QC, for both hemostasis and associated morbidity.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app