We have located links that may give you full text access.
Shear bond strength and microleakage results for three experimental self-etching primer compositions for pit and fissure sealing.
Clinical Oral Investigations 2017 June
OBJECTIVES: This in vitro study evaluated the shear bond strength (SBS) and microleakage of three experimental self-etching primers for pit and fissure sealing.
MATERIALS AND METHODS: The material used three formulations of an experimental fissure primer (EFP) applied without phosphoric acid etching (EFP-1/EFP-2/EFP-3) and one control group with sealant application after 30 s of acid etching. Four groups of sealants (n = 40 specimens/group) were tested for SBS, and a failure analysis was conducted after 1-day water storage, 3-month water storage, and 5000-fold thermocycling. In addition, microleakage was tested.
RESULTS: The SBSs of the EFPs (range 8.2 MPa (standard deviation 4.2) to 15.4 MPa (5.4)) were generally significantly lower than those of conventional fissure sealing (range 15.6 MPa (4.4) to 19.1 MPa (6.2)). The SBS of EFP-3 was better than that of the EFP-1 or EFP-2 formulations. Microleakage was significantly lower in the control group (1.1 %) than in the EFP-1 (3.8 %) and lower than in EFP-3 (7.7 %) group. In the (multiple) linear regression analysis, material and aging significantly influenced SBS.
CONCLUSIONS: The SBS of EFP-3 was 15 to 32 % lower than it was for the corresponding controls.
CLINICAL RELEVANCE: The SBS is lower, but the main potential benefit of this new approach is a reduced application time in clinical practice.
MATERIALS AND METHODS: The material used three formulations of an experimental fissure primer (EFP) applied without phosphoric acid etching (EFP-1/EFP-2/EFP-3) and one control group with sealant application after 30 s of acid etching. Four groups of sealants (n = 40 specimens/group) were tested for SBS, and a failure analysis was conducted after 1-day water storage, 3-month water storage, and 5000-fold thermocycling. In addition, microleakage was tested.
RESULTS: The SBSs of the EFPs (range 8.2 MPa (standard deviation 4.2) to 15.4 MPa (5.4)) were generally significantly lower than those of conventional fissure sealing (range 15.6 MPa (4.4) to 19.1 MPa (6.2)). The SBS of EFP-3 was better than that of the EFP-1 or EFP-2 formulations. Microleakage was significantly lower in the control group (1.1 %) than in the EFP-1 (3.8 %) and lower than in EFP-3 (7.7 %) group. In the (multiple) linear regression analysis, material and aging significantly influenced SBS.
CONCLUSIONS: The SBS of EFP-3 was 15 to 32 % lower than it was for the corresponding controls.
CLINICAL RELEVANCE: The SBS is lower, but the main potential benefit of this new approach is a reduced application time in clinical practice.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app